Scinovex
article Open AccessTop 1% cited

New tools for automated high-resolution cryo-EM structure determination in RELION-3

eLife · 2018 · Vol. 7
Jasenko ZivanovTakanori NakaneBjörn ForsbergDari KimaniusWim J. H. HagenErik LindahlSjors H. W. Scheres

Abstract

Here, we describe the third major release of RELION. CPU-based vector acceleration has been added in addition to GPU support, which provides flexibility in use of resources and avoids memory limitations. Reference-free autopicking with Laplacian-of-Gaussian filtering and execution of jobs from python allows non-interactive processing during acquisition, including 2D-classification, <i>de novo</i> model generation and 3D-classification. Per-particle refinement of CTF parameters and correction of estimated beam tilt provides higher resolution reconstructions when particles are at different heights in the ice, and/or coma-free alignment has not been optimal. Ewald sphere curvature correction improves resolution for large particles. We illustrate these developments with publicly available data sets: together with a Bayesian approach to beam-induced motion correction it leads to resolution improvements of 0.2-0.7 Å compared to previous RELION versions.

Particle Accelerators and Free-Electron LasersComputer sciencePython (programming language)Computational scienceAlgorithmCurvatureGraphicsArtificial intelligenceComputer engineeringComputer graphics (images)Mathematics

MeSH terms

Image Processing, Computer-AssistedCryoelectron MicroscopyAutomation, Laboratory

Funding

  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
  • Knut och Alice Wallenbergs Stiftelse
  • Vetenskapsrådet
  • Medical Research Council
  • Japan Society for the Promotion of Science
Citations
5,369
FWCI
298.99
field-weighted impact
References
70
Percentile
100%
vs. same field & year
Citations per year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

New tools for automated high-resolution cryo-EM structure determination in RELION-3 · Scinovex