The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization

Medical Physics · 1995 · Vol. 22(1) · pp. 37–53
Eros PedroniR. BacherH. BlattmannT. BöhringerAdolf CorayAntony LomaxShixiong LinGudrun MunkelStefan ScheibUwe SchneiderAlexander Tourovsky

Abstract

The new proton therapy facility is being assembled at the Paul Scherrer Institute (PSI). The beam delivered by the PSI sector cyclotron can be split and brought into a new hall where it is degraded from 590 MeV down to an energy in the range of 85-270 MeV. A new beam line following the degrader is used to clean the low-energetic beam in phase space and momentum band. The analyzed beam is then injected into a compact isocentric gantry, where it is applied to the patient using a new dynamic treatment modality, the so-called spot-scanning technique. This technique will permit full three-dimensional conformation of the dose to the target volume to be realized in a routine way without the need for individualized patient hardware like collimators and compensators. By combining the scanning of the focused pencil beam within the beam optics of the gantry and by mounting the patient table eccentrically on the gantry, the diameter of the rotating structure has been reduced to only 4 m. In the article the degrees of freedom available on the gantry to apply the beam to the patient (with two rotations for head treatments) are also discussed. The devices for the positioning of the patient on the gantry (x rays and proton radiography) and outside the treatment room (the patient transporter system and the modified mechanics of the computer tomograph unit) are briefly presented. The status of the facility and first experimental results are introduced for later reference.

Radiation Therapy and DosimetryParticle accelerators and beam dynamicsParticle Accelerators and Free-Electron LasersBeam (structure)CyclotronProton therapyPencil-beam scanningPhysicsDosimetryProtonBeamlineOpticsBragg peak

MeSH terms

HumansProtonsRadiation DosageRadiotherapySwitzerlandCyclotrons
Citations
582
FWCI
7.10
field-weighted impact
References
0
Percentile
97%
vs. same field & year
Citations per year
Cited by
Intensity modulation methods for proton radiotherapy
Physics in Medicine and Biology · 1999 · 533 citations
<i>In vivo</i>proton range verification: a review
Physics in Medicine and Biology · 2013 · 520 citations
The physics of proton therapy
Physics in Medicine and Biology · 2015 · 646 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization · Scinovex