Scinovex
articleTop 10% cited

Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization

Physics in Medicine and Biology · 2000 · Vol. 45(11) · pp. 3299–3317
Martina KrämerOliver JäkelT. HabererGerhard KraftD. SchardtUli Weber

Abstract

We describe a novel code system, TRiP, dedicated to the planning of radiotherapy with energetic ions, in particular 12C. The software is designed to cooperate with three-dimensional active dose shaping devices like the GSI raster scan system. This unique beam delivery system allows us to select any combination from a list of 253 individual beam energies, 7 different beam spot sizes and 15 intensity levels. The software includes a beam model adapted to and verified for carbon ions. Inverse planning techniques are implemented in order to obtain a uniform target dose distribution from clinical input data, i.e. CT images and patient contours. This implies the automatic generation of intensity modulated fields of heavy ions with as many as 40000 raster points, where each point corresponds to a specific beam position, energy and particle fluence. This set of data is directly passed to the beam delivery and control system. The treatment planning code has been in clinical use since the start of the GSI pilot project in December 1997. Forty-eight patients have been successfully planned and treated.

Radiation Therapy and DosimetryRadiation Detection and Scintillator TechnologiesAdvanced Radiotherapy TechniquesRadiation treatment planningBeam (structure)Computer scienceIon beamRaster graphicsParticle therapySoftwareRaster scanPhysicsMedical physics

MeSH terms

AlgorithmsHumansRadiometryRadiotherapy Planning, Computer-AssistedModels, StatisticalRadiotherapy, Conformal
Citations
488
FWCI
7.41
field-weighted impact
References
19
Percentile
97%
vs. same field & year
Citations per year
Cited by
Charged hadron tumour therapy monitoring by means of PET
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2004 · 384 citations
References
Magnetic scanning system for heavy ion therapy
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 1993 · 717 citations
Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
International Journal of Radiation Oncology*Biology*Physics · 1999 · 884 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization · Scinovex