Scinovex
articleTop 1% cited

Design and Fabrication of Soft Artificial Skin Using Embedded Microchannels and Liquid Conductors

IEEE Sensors Journal · 2012 · Vol. 12(8) · pp. 2711–2718
Yong‐Lae ParkBor‐Rong ChenRobert J. Wood

Abstract

We describe the design, fabrication, and calibration of a highly compliant artificial skin sensor. The sensor consists of multilayered mircochannels in an elastomer matrix filled with a conductive liquid, capable of detecting multiaxis strains and contact pressure. A novel manufacturing method comprised of layered molding and casting processes is demonstrated to fabricate the multilayered soft sensor circuit. Silicone rubber layers with channel patterns, cast with 3-D printed molds, are bonded to create embedded microchannels, and a conductive liquid is injected into the microchannels. The channel dimensions are 200 μm (width) × 300 μm (height). The size of the sensor is 25 mm × 25 mm, and the thickness is approximately 3.5 mm. The prototype is tested with a materials tester and showed linearity in strain sensing and nonlinearity in pressure sensing. The sensor signal is repeatable in both cases. The characteristic modulus of the skin prototype is approximately 63 kPa. The sensor is functional up to strains of approximately 250%.

Advanced Sensor and Energy Harvesting MaterialsAdvanced MEMS and NEMS TechnologiesAdhesion, Friction, and Surface InteractionsMaterials scienceFabricationSilicone rubberElastomerElectrical conductorMolding (decorative)LinearityPressure sensorComposite materialElectrode
Citations
765
FWCI
22.54
field-weighted impact
References
49
Percentile
100%
vs. same field & year
Citations per year
Cited by
Emerging Applications of Liquid Metals Featuring Surface Oxides
ACS Applied Materials & Interfaces · 2014 · 682 citations
Toward Perceptive Soft Robots: Progress and Challenges
Advanced Science · 2018 · 714 citations
A Soft Strain Sensor Based on Ionic and Metal Liquids
IEEE Sensors Journal · 2013 · 319 citations
3D-printed sensors: Current progress and future challenges
Sensors and Actuators A Physical · 2020 · 315 citations
References
The measurement of volume changes in human limbs
The Journal of Physiology · 1953 · 1,496 citations
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Analytical Chemistry · 1998 · 5,227 citations
Conductive polymer-based sensors for biomedical applications
Biosensors and Bioelectronics · 2010 · 505 citations
Sensitive skin
IEEE Sensors Journal · 2001 · 431 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.