Scinovex
article Open AccessTop 1% cited

Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRI

Magnetic Resonance in Medicine · 2010 · Vol. 63(5) · pp. 1144–1153
Steen MoellerEssa YacoubCheryl A. OlmanEdward J. AuerbachJohn StruppNoam HarelKâmil Uǧurbil

Abstract

Parallel imaging in the form of multiband radiofrequency excitation, together with reduced k-space coverage in the phase-encode direction, was applied to human gradient echo functional MRI at 7 T for increased volumetric coverage and concurrent high spatial and temporal resolution. Echo planar imaging with simultaneous acquisition of four coronal slices separated by 44mm and simultaneous 4-fold phase-encoding undersampling, resulting in 16-fold acceleration and up to 16-fold maximal aliasing, was investigated. Task/stimulus-induced signal changes and temporal signal behavior under basal conditions were comparable for multiband and standard single-band excitation and longer pulse repetition times. Robust, whole-brain functional mapping at 7 T, with 2 x 2 x 2mm(3) (pulse repetition time 1.25 sec) and 1 x 1 x 2mm(3) (pulse repetition time 1.5 sec) resolutions, covering fields of view of 256 x 256 x 176 mm(3) and 192 x 172 x 176 mm(3), respectively, was demonstrated with current gradient performance.

Advanced MRI Techniques and ApplicationsAtomic and Subatomic Physics ResearchAdvanced NMR Techniques and ApplicationsUndersamplingNuclear magnetic resonancePhysicsMultisliceTemporal resolutionExcitationOpticsComputer scienceArtificial intelligence

MeSH terms

AlgorithmsBrainBrain MappingEvoked PotentialsHumansImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingSensitivity and SpecificityReproducibility of ResultsImaging, Three-Dimensional

Funding

  • W. M. Keck Foundation
Citations
1,695
FWCI
22.89
field-weighted impact
References
30
Percentile
100%
vs. same field & year
Citations per year
References
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Proceedings of the National Academy of Sciences · 1992 · 4,233 citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Magnetic Resonance in Medicine · 2002 · 5,259 citations
SENSE: Sensitivity encoding for fast MRI
Magnetic Resonance in Medicine · 1999 · 6,058 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.