Scinovex
article Open AccessTop 1% cited

Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced <i>g</i>‐factor penalty

Magnetic Resonance in Medicine · 2011 · Vol. 67(5) · pp. 1210–1224
Kawin SetsompopBorjan GagoskiJon̈athan R. PolimeniThomas WitzelVan J. WedeenLawrence L. Wald

Abstract

Simultaneous multislice Echo Planar Imaging (EPI) acquisition using parallel imaging can decrease the acquisition time for diffusion imaging and allow full-brain, high-resolution functional MRI (fMRI) acquisitions at a reduced repetition time (TR). However, the unaliasing of simultaneously acquired, closely spaced slices can be difficult, leading to a high g-factor penalty. We introduce a method to create interslice image shifts in the phase encoding direction to increase the distance between aliasing pixels. The shift between the slices is induced using sign- and amplitude-modulated slice-select gradient blips simultaneous with the EPI phase encoding blips. This achieves the desired shifts but avoids an undesired "tilted voxel" blurring artifact associated with previous methods. We validate the method in 3× slice-accelerated spin-echo and gradient-echo EPI at 3 T and 7 T using 32-channel radio frequency (RF) coil brain arrays. The Monte-Carlo simulated average g-factor penalty of the 3-fold slice-accelerated acquisition with interslice shifts is <1% at 3 T (compared with 32% without slice shift). Combining 3× slice acceleration with 2× inplane acceleration, the g-factor penalty becomes 19% at 3 T and 10% at 7 T (compared with 41% and 23% without slice shift). We demonstrate the potential of the method for accelerating diffusion imaging by comparing the fiber orientation uncertainty, where the 3-fold faster acquisition showed no noticeable degradation.

Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMRI in cancer diagnosisAliasingEcho-planar imagingMultisliceArtifact (error)Orientation (vector space)AccelerationDiffusion MRIVoxelComputer scienceNuclear magnetic resonance

MeSH terms

AlgorithmsBrainHumansImage EnhancementImage Interpretation, Computer-AssistedPattern Recognition, AutomatedSensitivity and SpecificitySignal Processing, Computer-AssistedReproducibility of ResultsArtifactsEcho-Planar ImagingImaging, Three-Dimensional

Funding

  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering
  • National Center for Research Resources
  • NIH Blueprint for Neuroscience Research
Citations
1,347
FWCI
27.70
field-weighted impact
References
30
Percentile
100%
vs. same field & year
Citations per year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.