Scinovex
articleTop 10% cited

Optimizing the exercise protocol for cardiopulmonary assessment

Journal of Applied Physiology · 1983 · Vol. 55(5) · pp. 1558–1564

Abstract

Twelve normal men performed 1-min incremental exercise tests to exhaustion in approximately 10 min on both treadmill and cycle ergometer. The maximal O2 uptake (VO2 max) and anaerobic threshold (AT) were higher (6 and 13%, respectively) on the treadmill than the cycle; the AT was reached at about 50% of VO2 max on both ergometers. Maximal CO2 output, heart rate, and O2 pulse were also slightly, but significantly higher on the treadmill. Maximal ventilation, gas exchange ratio, and ventilatory equivalents for O2 and CO2 for both forms of exercise were not significantly different. To determine the optimum exercise test for both treadmill and cycle, we exercised five of the subjects at various work rate increments on both ergometers in a randomized design. The treadmill increments were 0.8, 1.7, 2.5, and 4.2%/min at a constant speed of 3.4 mph, and 1.7 and 4.2%/min at 4.5 mph. Cycle increments were 15, 30, and 60 W/min. The VO2 max was significantly higher on tests where the increment magnitude was large enough to induce test durations of 8-17 min, but the AT was independent of test duration. Thus, for evaluating cardiopulmonary function with incremental exercise testing by either treadmill or cycle, we suggest selecting a work rate increment to bring the subject to the limit of his tolerance in about 10 min.

Cardiovascular and exercise physiologySports Performance and TrainingCardiovascular Effects of ExerciseTreadmillAnaerobic exerciseRespiratory exchange ratioIncremental exerciseCycle ergometerWork rateVO2 maxHeart rateVentilation (architecture)Ventilatory threshold

MeSH terms

AdultAnaerobiosisDifferential ThresholdExercise TestHeartHeart RateHumansLungMiddle AgedOxygen Consumption
Citations
863
FWCI
3.83
field-weighted impact
References
17
Percentile
93%
vs. same field & year
Citations per year
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
American Journal of Respiratory and Critical Care Medicine · 2003 · 2,082 citations
ATS/ACCP Statement on Cardiopulmonary Exercise Testing
American Journal of Respiratory and Critical Care Medicine · 2003 · 2,930 citations
References
Anaerobic threshold and respiratory gas exchange during exercise.
Journal of Applied Physiology · 1973 · 2,065 citations
Related articles
Optimizing the exercise protocol for cardiopulmonary assessment
Journal of Applied Physiology · 1983 · 863 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Optimizing the exercise protocol for cardiopulmonary assessment · Scinovex