Scinovex
articleTop 1% cited

Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing

IEEE Transactions on Biomedical Engineering · 2006 · Vol. 53(7) · pp. 1346–1356
A.M. Sabatini

Abstract

In this paper, a quaternion based extended Kalman filter (EKF) is developed for determining the orientation of a rigid body from the outputs of a sensor which is configured as the integration of a tri-axis gyro and an aiding system mechanized using a tri-axis accelerometer and a tri-axis magnetometer. The suggested applications are for studies in the field of human movement. In the proposed EKF, the quaternion associated with the body rotation is included in the state vector together with the bias of the aiding system sensors. Moreover, in addition to the in-line procedure of sensor bias compensation, the measurement noise covariance matrix is adapted, to guard against the effects which body motion and temporary magnetic disturbance may have on the reliability of measurements of gravity and earth's magnetic field, respectively. By computer simulations and experimental validation with human hand orientation motion signals, improvements in the accuracy of orientation estimates are demonstrated for the proposed EKF, as compared with filter implementations where either the in-line calibration procedure, the adaptive mechanism for weighting the measurements of the aiding system sensors, or both are not implemented.

Inertial Sensor and NavigationIndoor and Outdoor Localization TechnologiesTarget Tracking and Data Fusion in Sensor NetworksExtended Kalman filterQuaternionKalman filterAccelerometerControl theory (sociology)Orientation (vector space)Invariant extended Kalman filterGyroscopeInertial measurement unitRotation matrix

MeSH terms

AccelerationAlgorithmsBiomechanical PhenomenaComputer SimulationDiagnosis, Computer-AssistedFiltrationHandHumansMagneticsModels, BiologicalMovementOrientation
Citations
864
FWCI
248.51
field-weighted impact
References
29
Percentile
100%
vs. same field & year
Citations per year
Cited by
Gait Analysis Using Wearable Sensors
Sensors · 2012 · 1,139 citations
A High Reliability Wearable Device for Elderly Fall Detection
IEEE Sensors Journal · 2015 · 273 citations
Zero-Velocity Detection—An Algorithm Evaluation
IEEE Transactions on Biomedical Engineering · 2010 · 634 citations
References
Assessment of Walking Features From Foot Inertial Sensing
IEEE Transactions on Biomedical Engineering · 2005 · 642 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing · Scinovex