Scinovex
articleTop 10% cited

Nonlinear sinogram smoothing for low-dose X-ray CT

IEEE Transactions on Nuclear Science · 2004 · Vol. 51(5) · pp. 2505–2513
Tianfang LiXiang LiJing WangJunhai WenHongbing LuJiang HsiehZhengrong Liang

Abstract

When excessive quantum noise is present in extremely low dose X-ray CT imaging, statistical properties of the data has to be considered to achieve a satisfactory image reconstruction. Statistical iterative reconstruction with accurate modeling of the noise, rather than a filtered back-projection (FBP) with low-pass filtering, is one way to deal with the problem. Estimating a noise-free sinogram to satisfy the FBP reconstruction for the Radon transform is another way. The benefits of the latter include a higher computation efficiency, more uniform spatial resolution in the reconstructed image, and less modification of the current machine configurations. In a clinic X-ray CT system, the acquired raw data must be calibrated, in addition to the logarithmic transform, to achieve the high diagnostic image quality. The calibrated projection data or sinogram no longer follow a compound Poisson distribution in general, but are close to a Gaussian distribution with signal-dependent variance. In this paper, we first investigated a relatively accurate statistical model for the sinogram data, based on several phantom experiments. Then we developed a penalized likelihood method to smooth the sinogram, which led to a set of nonlinear equations that can be solved by iterated conditional mode (ICM) algorithm within a reasonable computing time. The method was applied to several experimental datasets acquired at 120 kVp, 10 mA/20 mA/50 mA protocols with a GE HiSpeed multi-slice detector CT scanner and demonstrated a significant noise suppression without noticeable sacrifice of the spatial resolution.

Medical Imaging Techniques and ApplicationsAdvanced X-ray and CT ImagingRadiation Dose and ImagingIterative reconstructionRadon transformImaging phantomNoise (video)Shot noiseSmoothingAlgorithmImage resolutionProjection (relational algebra)Image quality
Citations
305
FWCI
5.71
field-weighted impact
References
21
Percentile
96%
vs. same field & year
Citations per year
Cited by
Low-Dose X-ray CT Reconstruction via Dictionary Learning
IEEE Transactions on Medical Imaging · 2012 · 679 citations
References
On the Statistical Analysis of Dirty Pictures
Journal of the Royal Statistical Society Series B (Statistical Methodology) · 1986 · 4,213 citations
Stochastic Relaxation, Gibbs Distributions, and the Bayesian Restoration of Images
IEEE Transactions on Pattern Analysis and Machine Intelligence · 1984 · 17,882 citations
Statistical image reconstruction for polyenergetic X-ray computed tomography
IEEE Transactions on Medical Imaging · 2002 · 685 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.