Scinovex
articleTop 1% cited

N4ITK: Improved N3 Bias Correction

IEEE Transactions on Medical Imaging · 2010 · Vol. 29(6) · pp. 1310–1320
Nicholas J. TustisonBrian AvantsPhilip A. CookYuanjie ZhengAlexander EganPaul A. YushkevichJames C. Gee

Abstract

A variant of the popular nonparametric nonuniform intensity normalization (N3) algorithm is proposed for bias field correction. Given the superb performance of N3 and its public availability, it has been the subject of several evaluation studies. These studies have demonstrated the importance of certain parameters associated with the B-spline least-squares fitting. We propose the substitution of a recently developed fast and robust B-spline approximation routine and a modified hierarchical optimization scheme for improved bias field correction over the original N3 algorithm. Similar to the N3 algorithm, we also make the source code, testing, and technical documentation of our contribution, which we denote as "N4ITK," available to the public through the Insight Toolkit of the National Institutes of Health. Performance assessment is demonstrated using simulated data from the publicly available Brainweb database, hyperpolarized (3)He lung image data, and 9.4T postmortem hippocampus data.

Advanced NMR Techniques and ApplicationsImage and Signal Denoising MethodsSparse and Compressive Sensing TechniquesComputer scienceNormalization (sociology)Spline (mechanical)AlgorithmNonparametric statisticsArtificial intelligenceData miningMathematicsStatistics

MeSH terms

AlgorithmsBrainHumansImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingSensitivity and SpecificityReproducibility of ResultsArtifacts

Funding

  • University of Virginia
Citations
6,231
FWCI
11.79
field-weighted impact
References
28
Percentile
99%
vs. same field & year
Citations per year
Cited by
Brain Tumor Segmentation Using Convolutional Neural Networks in MRI Images
IEEE Transactions on Medical Imaging · 2016 · 2,615 citations
fMRIPrep: a robust preprocessing pipeline for functional MRI
Nature Methods · 2018 · 4,013 citations
The Multimodal Brain Tumor Image Segmentation Benchmark (BRATS)
IEEE Transactions on Medical Imaging · 2014 · 6,268 citations
References
Design and construction of a realistic digital brain phantom
IEEE Transactions on Medical Imaging · 1998 · 1,823 citations
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
IEEE Transactions on Medical Imaging · 2007 · 834 citations
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
IEEE Transactions on Medical Imaging · 1998 · 4,793 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.