Scinovex
articleTop 10% cited

Fast calculation of the exact radiological path for a three‐dimensional CT array

Medical Physics · 1985 · Vol. 12(2) · pp. 252–255
Robert L. Siddon

Abstract

Ready availability has prompted the use of computed tomography (CT) data in various applications in radiation therapy. For example, some radiation treatment planning systems now utilize CT data in heterogeneous dose calculation algorithms. In radiotherapy imaging applications, CT data are projected onto specified planes, thus producing “radiographs,” which are compared with simulator radiographs to assist in proper patient positioning and delineation of target volumes. All these applications share the common geometric problem of evaluating the radiological path through the CT array. Due to the complexity of the three‐dimensional geometry and the enormous amount of CT data, the exact evaluation of the radiological path has proven to be a time consuming and difficult problem. This paper identifies the inefficient aspect of the traditional exact evaluation of the radiological path as that of treating the CT data as individual voxels. Rather than individual voxels, a new exact algorithm is presented that considers the CT data as consisting of the intersection volumes of three orthogonal sets of equally spaced, parallel planes. For a three‐dimensional CT array of N 3 voxels, the new exact algorithm scales with 3 N , the number of planes, rather than N 3 , the number of voxels. Coded in fortran‐77 on a VAX 11/780 with a floating point option, the algorithm requires approximately 5 ms to calculate an average radiological path in a 100 3 voxel array.

Advanced Radiotherapy TechniquesMedical Imaging Techniques and ApplicationsMedical Image Segmentation TechniquesVoxelComputer scienceRadiological weaponPath (computing)Radiation treatment planningMedical imagingIntersection (aeronautics)RadiographyDosimetryAlgorithm
Citations
1,502
FWCI
3.61
field-weighted impact
References
0
Percentile
93%
vs. same field & year
Citations per year
Cited by
STIR: software for tomographic image reconstruction release 2
Physics in Medicine and Biology · 2012 · 470 citations
The physics of proton therapy
Physics in Medicine and Biology · 2015 · 646 citations
Dose calculations for external photon beams in radiotherapy
Physics in Medicine and Biology · 1999 · 493 citations
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
IEEE Transactions on Medical Imaging · 2017 · 1,776 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.