article Open AccessTop 1% cited
Performance of fourier domain vs time domain optical coherence tomography
Optics Express · 2003 · Vol. 11(8) · pp. 889–889
Rainer A. Leitgeb✉(University of Vienna)Christoph K. Hitzenberger(University of Vienna)Adolf F. Fercher(University of Vienna)
Abstract
In this article we present a detailed discussion of noise sources in Fourier Domain Optical Coherence Tomography (FDOCT) setups. The performance of FDOCT with charge coupled device (CCD) cameras is compared to current standard time domain OCT systems. We describe how to measure sensitivity in the case of FDOCT and confirm the theoretically obtained values. It is shown that FDOCT systems have a large sensitivity advantage and allow for sensitivities well above 80dB, even in situations with low light levels and high speed detection.
Optical Coherence Tomography ApplicationsPhotoacoustic and Ultrasonic ImagingRetinal and Macular SurgeryOptical coherence tomographyOpticsFourier transformPhysicsFourier domainTime domainSensitivity (control systems)Coherence (philosophical gambling strategy)Noise (video)Computer science
Funding
- Oesterreichische Nationalbank
Citations
1,824
FWCI
55.86
field-weighted impact
References
11
Percentile
100%
vs. same field & year
Citations per year
Cited by
Sensitivity of OCT and OCTA metrics in grading of hypertensive retinopathy
International Journal of Medical Ophthalmology · 2023 · 0 citations
Optical coherence tomography - current and future Applications
International Journal of Medical Ophthalmology · 2023 · 0 citations
Three dimensional optical angiography
Optics Express · 2007 · 626 citations
Optical coherence angiography
Optics Express · 2006 · 607 citations
The Development, Commercialization, and Impact of Optical Coherence Tomography
Investigative Ophthalmology & Visual Science · 2016 · 458 citations
High-speed optical frequency-domain imaging
Optics Express · 2003 · 856 citations
Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation
Optics Express · 2004 · 1,029 citations
Theory, developments and applications of optical coherence tomography
Journal of Physics D Applied Physics · 2005 · 628 citations
References
Measurement of intraocular distances by backscattering spectral interferometry
Optics Communications · 1995 · 1,195 citations
The Fourier Transform and Its Applications
American Journal of Physics · 1966 · 5,454 citations
Citation Network
How this paper connects to the literature. Drag to explore, click any node to open that paper.
