Scinovex
articleTop 1% cited

Microscopic susceptibility variation and transverse relaxation: Theory and experiment

Magnetic Resonance in Medicine · 1994 · Vol. 31(6) · pp. 601–610
Robert M. WeisskoffChun S. ZuoJerrold L. BoxermanBruce R. Rosen

Abstract

Microscopic susceptibility variations invariably increase apparent transverse relaxation rates. In this paper, we present comparisons between Monte Carlo simulations and experiments with polystyrene microspheres to demonstrate that this enhanced relaxation can be explained quantitatively for both spin echo and gradient echo imaging experiments. The spheres used (1 to 30 microms), and degree of susceptibility variation (caused by 0-12 mM Dy-DTPA) covered a wide range of biologically relevant compartment sizes and contrast agent concentrations. These results show that several regimes of behavior exist, and that contrast dependence is quite different in these regimes. For a given susceptibility, delta chi, a small range of particle sizes show peak transverse relaxation. For the range of susceptibilities found in the first pass of a clinical IV contrast agent bolus, this size range is 5 to 10 microns, or roughly capillary sized compartments. In both our simulations and experiments, smaller spheres showed quadratic relaxation versus concentration curves, and larger particles showed sublinear behavior. For particles corresponding to the peak relaxivity, the relaxation-concentration curves were linear. In addition, we demonstrated that increasing the diffusion coefficient can increase, decrease, or, paradoxically, leave unaffected the apparent relaxation rate. The regime for which the diffusion coefficient is relatively unimportant corresponds to the region of peak relaxivity. By using the Bloch-Torrey equation to produce scaling rules, the specific Monte Carlo simulations were extended to more general cases. We use these scaling rules to demonstrate why we often find that susceptibility-induced relaxation rates vary approximately linearly with concentration of injected agent.

Advanced MRI Techniques and ApplicationsLanthanide and Transition Metal ComplexesElectron Spin Resonance StudiesRelaxation (psychology)ScalingMonte Carlo methodDiffusionNuclear magnetic resonanceRange (aeronautics)ChemistryMaterials scienceMolecular physicsCondensed matter physics

MeSH terms

AnimalsComputer SimulationContrast MediaDiffusionPentetic AcidDysprosiumHumansImage EnhancementMagnetic Resonance ImagingMicrospheresModels, BiologicalModels, ChemicalModels, TheoreticalMonte Carlo MethodMagnetic Resonance Spectroscopy
Citations
714
FWCI
18.05
field-weighted impact
References
42
Percentile
100%
vs. same field & year
Citations per year
References
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Proceedings of the National Academy of Sciences · 1992 · 4,233 citations
Time course EPI of human brain function during task activation
Magnetic Resonance in Medicine · 1992 · 1,940 citations
Spin Echoes
Physical Review · 1950 · 4,891 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.