Scinovex
article Open Access

Calculation of exergy destruction of various components by performing exergy analysis on stage-i of Dr. Narla Tatarao thermal power station (N.T.T.P.S)

International Journal of Advanced Academic Studies · 2019 · Vol. 1(1) · pp. 01–06

Abstract

For any nation to develop power generation plays a crucial role. The performance of a power plant is analyzed by using the Energy balance and it is done by using the first law of thermodynamics. But to know how much energy is being utilized in reality exergy analysis has to be performed which is also called as second law of thermodyanamic analysis because the vital parameter quality is being considered in the exergy analysis. This paper deals with the exergy destruction calculation by performing exergy analysis for various components for a 210 mw plant of vijaywada thermal power station (Stage-1 Unit-1) and from the analysis it is clear that exergy destruction is more in condenser.

Process Optimization and IntegrationPhotovoltaic System Optimization TechniquesRenewable energy and sustainable power systemsExergyCondenser (optics)Exergy efficiencySecond law of thermodynamicsThermal power stationStage (stratigraphy)First law of thermodynamicsPower stationPower (physics)Thermodynamics
Citations
0
FWCI
0.00
field-weighted impact
References
0
Percentile
35%
vs. same field & year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Calculation of exergy destruction of various components by performing exergy analysis on stage-i of Dr. Narla Tatarao thermal power station (N.T.T.P.S) · Scinovex