Scinovex
paratext Open Access

Untitled

C FemilRahul RavichandranHarsha Kumar KVivek V NairKavitha JanardananT SawaseA WennerbergC HallgrenI MiyamotoT AlbrektssonM QuirynenH Van Der MeiCml BollenA SchotteM MarechalG DoornbuschM QuirynenM MarechalH BusscherA WeerkampJ ArendsP DariusC BollenW PapaioannoJ Van EldereE SchepersM QuirynenD Van SteenbergheI EricssonT BerglundhC MarinelloB LiljenbergJ LindheT BerglundhJ LindheK JonssonI EricssonT BerglundhK GotfredsenN ZitzmannN LangJ LindheJ LindheT BerglundhI EricssonB LiljenbergC MarinelloA MombelliMac Van OostenSchrch JrE LangNK HydenrjikJ MajjerH GuptaA GargN BediP ApseR EllenC OverallG ZarbD SteinbergA KlingerD KohaviM SelaS DhirW TeughelsN Van AsscheI SliepenM QuirynenM QuirynenM MarechalH BusscherA WeerkampP DariusD Van SteenbergheC BollenW PapaioannoJ Van EldereE SchepersM QuirynenD Van SteenbergheM QuirynenC BollenW PapaioannouJ Van EldereD Van SteenbergheL RimondiniS FarE BrambillaA FelloniC ConsonniF BrossaO CarcuacI AbrahamssonJ AlbouyE LinderL LarssonT BerglundhA WennerbergL SennerbyC KultjeU LekholmT SawaseA WennerbergC HallgrenT AlbrektssonK Baba

Abstract

The resistance of the periimplant tissues to inflammation is evidently much lower with the implant than that of natural teeth. In order to maintain periimplant health, and prevent implant failure, it is important to understand the relationship between abutment surface characteristics and plaque attachment. The aim of this study is to assess whether the surface roughness of three commercially available dental implant abutments are less than or equal to the clinical threshold value R(a) 0.2m for bacterial retention that may eventually contribute to periimplantitis. Abutments from Adin , Nobel Biocare, and Myriad implant systems are sectioned into 22 mm dimension samples using High Speed Stainless cutting tools. To investigate the surface microstructure of the samples, three dimensional imaging and numeric analysis are done using AFM (Atomic Force Microscope). The results showed that the surface roughness values of the three groups Adin, Myriad and Nobel Biocare are less than the clinical threshold value R(a) 0.2m and among them Myriad has the least surface roughness. Since the surface roughnesses are less than 0.2 m, it was concluded that professionals can give preference to any of the abutments systems.

Medicine
Citations
0
FWCI
field-weighted impact
References
17
Percentile
vs. same field & year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.