Management of validation of HPLC method for determination of acetylsalicylic acid impurities in a new pharmaceutical product

Scientific Reports · 2022 · Vol. 12(1) · pp. 1–1
Małgorzata KowalskaMagdalena WoźniakMichał KijekPaulina MitroszJerzy SzakielPaweł Turek

Abstract

The work mainly focused on a validation of the method for determining the content of salicylic acid and individual unknown impurities in new pharmaceutical product-tablets containing: 75, 100 or 150 mg of acetylsalicylic acid and glycine in the amount of 40 mg for each dosage. The separation of the components was carried out by means of HPLC, using a Waters Symmetry C18 column (4.6 × 250 mm, 5 μm) as the stationary phase. The mobile phase consisted of a mixture of 85% orthophosphoric acid, acetonitrile and purified water (2:400:600 V/V/V). Detection was carried out at a wavelength of 237 nm, with a constant flow rate of 1.0 ml min<sup>-1</sup>. In order to verify the method, linearity, precision (repeatability and reproducibility), accuracy, specificity, range, robustness, system precision, stability of the test and standard solution, limit of quantification and forced degradation were determined. Validation tests were performed in accordance with ICH (International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use) guidelines. The method was validated successfully. It was confirmed that the method in a tested range of 0.005-0.40% salicylic acid with respect to acetylsalicylic acid content is linear, precise and accurate.

Analytical Methods in PharmaceuticalsAnalytical Chemistry and ChromatographyInflammatory mediators and NSAID effectsRepeatabilityChromatographySalicylic acidReproducibilityHigh-performance liquid chromatographyImpurityDetection limitAcetonitrileChemistryLinearity

MeSH terms

AspirinChromatography, High Pressure LiquidDrug ContaminationGlycineSensitivity and SpecificityTabletsReproducibility of ResultsLimit of Detection

Funding

  • Uniwersytet Ekonomiczny w Krakowie
Citations
2,098
FWCI
210.20
field-weighted impact
References
15
Percentile
100%
vs. same field & year
Citations per year
References
Guidelines from the International Conference on Harmonisation (ICH)
Journal of Pharmaceutical and Biomedical Analysis · 2005 · 318 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Management of validation of HPLC method for determination of acetylsalicylic acid impurities in a new pharmaceutical product · Scinovex