Scinovex
articleTop 1% cited

How to treat raw sewage with constructed wetlands: an overview of the French systems

Water Science & Technology · 2005 · Vol. 51(9) · pp. 11–21
Pascal MolleA. LiénardCatherine BoutinGérard MerlinA. Iwema

Abstract

The development of vertical flow constructed wetlands treating raw wastewater in France has proved to be very successful over the last 20 years. In view of this a survey was carried out on more than 80 plants in order to study their performance and correct the design if necessary. This study shows that such systems perform well in terms of respecting the goals of both low level outlet COD and SS and nitrification. Pollutant removal performance in relation to the loads handled and the specific characteristics of the plants were investigated. Nitrification is shown to be the most sensitive process in such systems and performance in relation to sizing is discussed. Such systems, if well designed, can achieve an outlet level of 60 mg L(-1) in COD, 15 mg L(-1) in SS and 8 mg L(-1) in TKN with an area of 2 - 2.5 m2.PE(-1). The sludge deposit on the first stage must be removed after about 10-15 years.

Constructed Wetlands for Wastewater TreatmentWastewater Treatment and Nitrogen RemovalNitrificationSizingKjeldahl methodWastewaterEnvironmental scienceWetlandSewageEnvironmental engineeringSewage treatmentConstructed wetland

MeSH terms

Biodegradation, EnvironmentalEnvironment DesignFranceNitrogenSewageWaste Disposal, FluidWater MovementsWater PollutantsEcosystem
Citations
310
FWCI
17.52
field-weighted impact
References
4
Percentile
99%
vs. same field & year
Citations per year
Cited by
Constructed Wetlands for Wastewater Treatment
Water · 2010 · 1,168 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.