Scinovex
article Open Access

Supracutaneous locking compression plate as an external fixator in compound metaphyseal and diaphyseal fractures of tibia

International Journal of Orthopaedics Sciences · 2020 · Vol. 6(3) · pp. 633–636
Akhil BansalSourabh AlawaDeependra SonkarArvind KaroriaAnshul KhareSanjiv Gaur

Abstract

Background: Most of lower leg external fixation are bulky and cumbersome and provides only temporary bony stabilization. Anatomically pre-contoured supracutaneous LCP has been utilized by many authors as an external fixator in patients with metaphyseal and diaphyseal fractures of tibia. Aim: The aim of this study is to analyse the end result of Supracutaneous LCP as a definitive external fixation and its effect on rate of union in metaphyseal and diaphyseal fractures. Materials and methods: A complete of 30 patients of compound fractures of tibia underwent “supracutaneous plating” of the tibia using an LCP. Average age was 44 years. Regular screw tract dressings were done. Average period of follow-up was 13 months. Results: The plate was kept ex situ for a period of 24-30 weeks. Proximal metaphysis, diaphysis and distal metaphysis united in 14 weeks, 20 weeks and 16 weeks respectively. Total of 30 patients were operated for Supracutaneous LCP of which one complicated with Infected Non-union resulting in implant removal and other complicated with Non-union which later underwent internal fixation. Conclusion: In compound fractures of tibia supracutaneous LCP are often used as a definitive external fixator because it gives good results especially for metaphyseal fractures and fewer complication rates, with Adequate stability. Advantageous effect of LCP in facilitating wound healing, cosmetic surgery procedure. Because it does not strike the contralateral leg therefore cosmetically acceptable and functional while ambulation. Because of nonoverlapping of implants fracture healing is easily assessed on x rays.

Bone fractures and treatmentsMusculoskeletal Disorders and RehabilitationHip and Femur FracturesMedicineMetaphysisTibiaDiaphysisSurgeryExternal fixationFixation (population genetics)ImplantBone healingExternal fixator
Citations
2
FWCI
0.15
field-weighted impact
References
23
Percentile
53%
vs. same field & year
Citations per year
References
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
The American Journal of the Medical Sciences · 1967 · 1,632 citations
Supracutaneous plate: A comparable alternative to external fixator in the treatment of open fracture
International Journal of Orthopaedics Sciences · 2018 · 5 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Supracutaneous locking compression plate as an external fixator in compound metaphyseal and diaphyseal fractures of tibia · Scinovex