Scinovex
article Open AccessTop 1% cited

Comparing Methods for Calculating Nano Crystal Size of Natural Hydroxyapatite Using X-Ray Diffraction

Nanomaterials · 2020 · Vol. 10(9) · pp. 1627–1627
Marzieh RabieiArvydas PalevičiusAhmad MonshiSohrab NasiriAndrius VilkauskasGiedrius Janušas

Abstract

We report on a comparison of methods based on XRD patterns for calculating crystal size. In this case, XRD peaks were extracted from hydroxyapatite obtained from cow, pig, and chicken bones. Hydroxyapatite was synthesized through the thermal treatment of natural bones at 950 °C. XRD patterns were selected by adjustment of X-Pert software for each method and for calculating the size of the crystals. Methods consisted of Scherrer (three models), Monshi-Scherrer, three models of Williamson-Hall (namely the Uniform Deformation Model (UDM), the Uniform Stress Deformation Model (USDM), and the Uniform Deformation Energy Density Model (UDEDM)), Halder-Wanger (H-W), and the Size Strain Plot Method (SSP). These methods have been used and compared together. The sizes of crystallites obtained by the XRD patterns in each method for hydroxyapatite from cow, pig, and chicken were 1371, 457, and 196 nm in the Scherrer method when considering all of the available peaks together (straight line model). A new model (straight line passing the origin) gave 60, 60, and 53 nm, which shows much improvement. The average model gave 56, 58, and 52 nm, for each of the three approaches, respectively, for cow, pig, and chicken. The Monshi-Scherrer method gave 60, 60, and 57 nm. Values of 56, 62, and 65 nm were given by the UDM method. The values calculated by the USDM method were 60, 62, and 62 nm. The values of 62, 62, and 65 nm were given by the UDEDM method for cow, pig, and chicken, respectively. Furthermore, the crystal size value was 4 nm for all samples in the H-W method. Values were also calculated as 43, 62, and 57 nm in the SSP method for cow, pig, and chicken tandemly. According to the comparison of values in each method, the Scherrer method (straight line model) for considering all peaks led to unreasonable values. Nevertheless, other values were in the acceptable range, similar to the reported values in the literature. Experimental analyses, such as specific surface area by gas adsorption (Brunauer-Emmett-Teller (BET)) and Transmission Electron Microscopy (TEM), were utilized. In the final comparison, parameters of accuracy, ease of calculations, having a check point for the researcher, and difference between the obtained values and experimental analysis by BET and TEM were considered. The Monshi-Scherrer method provided ease of calculation and a decrease in errors by applying least squares to the linear plot. There is a check point for this line that the slope must not be far from one. Then, the intercept gives the most accurate crystal size. In this study, the setup of values for BET (56, 52, and 49 nm) was also similar to the Monshi-Scherrer method and the use of it in research studies of nanotechnology is advised.

Bone Tissue Engineering MaterialsX-ray Diffraction in CrystallographyPigment Synthesis and PropertiesMaterials scienceNano-DiffractionCrystal (programming language)Natural (archaeology)X-ray crystallographyNanotechnologyCrystallographyComposite materialComputer science

Funding

  • Lietuvos Mokslo Taryba
Citations
458
FWCI
19.45
field-weighted impact
References
44
Percentile
100%
vs. same field & year
Citations per year
Cited by
Precise calculation of crystallite size of nanomaterials: A review
Journal of Alloys and Compounds · 2023 · 480 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.