Evaluation of clinical performance of self etching-self adhesive composite (Constic) ® compared with total etching composite system in primary teeth
Abstract
Aim of the study is to evaluate the clinical performance of self-etching, self-adhesive composite (Constic ®) in comparison with conventional composite with total-etch bonding system in primary teeth. Materials and methods: included comparing clinical performance of 2 different types of composite resins. Working time, restoration failure (recurrent caries – breakage – loss of restoration), post-treatment sensitivity, development of gingival abscess, recurrent caries visible on x-ray, radiographic abscess or periapical lesion were studied for both restorations. Clinical and radiographic observation was done every 3 months for 9 months for both restorations. Results: Clinical results showed substantial differences between the two types of composite in favor of self- etching, self-adhesive composite (Constic®) against the conventional one when working time length was compared (p< 0.0005). However, clinical results over the observation duration of both restorations showed that they have almost the same clinical performance with no statistically significant difference.
How this paper connects to the literature. Drag to explore, click any node to open that paper.