Scinovex
articleTop 1% cited

Generative Adversarial Networks for Noise Reduction in Low-Dose CT

IEEE Transactions on Medical Imaging · 2017 · Vol. 36(12) · pp. 2536–2545
Jelmer M. WolterinkTim LeinerMax A. ViergeverIvana Išgum

Abstract

Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.

Advanced X-ray and CT ImagingMedical Imaging Techniques and ApplicationsRadiation Dose and ImagingImaging phantomDiscriminatorArtificial intelligenceConvolutional neural networkComputer scienceNoise (video)Pattern recognition (psychology)Noise reductionReduction (mathematics)Computer vision

MeSH terms

ArteriesCalcinosisHumansImage Processing, Computer-AssistedTomography, X-Ray ComputedPhantoms, ImagingSignal-To-Noise Ratio
Citations
1,027
FWCI
46.04
field-weighted impact
References
56
Percentile
100%
vs. same field & year
Citations per year
References
Quantification of coronary artery calcium using ultrafast computed tomography
Journal of the American College of Cardiology · 1990 · 7,636 citations
Computed Tomography — An Increasing Source of Radiation Exposure
New England Journal of Medicine · 2007 · 8,611 citations
Automatic Segmentation of MR Brain Images With a Convolutional Neural Network
IEEE Transactions on Medical Imaging · 2016 · 768 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.