Scinovex
articleTop 10% cited

Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters

IEEE Transactions on Industrial Electronics · 2007 · Vol. 54(6) · pp. 3323–3334
Lennart HarneforsMassimo BongiornoStefan Lundberg

Abstract

A controlled power electronic converter can cause local instabilities when interacting with other dynamic subsystems in a power system. Oscillations at a certain frequency cannot, however, build up if the converter differential input admittance has a positive conductance (real part) at that frequency, since power is then dissipated. In this paper, input-admittance expressions for a voltage-source converter are derived. It is seen how the admittance can be shaped in order to get a positive real part in the desired frequency regions by adjusting the controller parameters.

Microgrid Control and OptimizationAdvanced DC-DC ConvertersReal-time simulation and control systemsAdmittanceConvertersControl theory (sociology)Voltage sourceController (irrigation)VoltagePower (physics)EngineeringComputer scienceElectronic engineering
Citations
1,097
FWCI
9.67
field-weighted impact
References
19
Percentile
98%
vs. same field & year
Citations per year
Cited by
Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
IEEE Transactions on Power Electronics · 2013 · 997 citations
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
IEEE Transactions on Power Electronics · 2015 · 1,270 citations
Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
IEEE Transactions on Power Electronics · 2014 · 762 citations
Impedance-Based Stability Criterion for Grid-Connected Inverters
IEEE Transactions on Power Electronics · 2011 · 2,418 citations
Unified Impedance Model of Grid-Connected Voltage-Source Converters
IEEE Transactions on Power Electronics · 2017 · 861 citations
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
IEEE Transactions on Power Systems · 2009 · 1,266 citations
Microgrid Stability Definitions, Analysis, and Examples
IEEE Transactions on Power Systems · 2019 · 713 citations
References
Model-based current control of AC machines using the internal model control method
IEEE Transactions on Industry Applications · 1998 · 619 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters · Scinovex