Abstract

A theoretical development is presented which results in a relationship between the expectation value of the standard deviation of the frequency fluctuations for any finite number of data samples and the infinite time average value of the standard deviation, which provides an invariant measure of an important quality factor of a frequency standard. A practical and straightforward method of determining the power spectral density of the frequency fluctuations from the variance of the frequency fluctuations, the sampling time, the number of samples taken, and the dependence on system bandwidth is also developed. Additional insight is also given into some of the problems that arise from the presence of "flicker noise" (spectrum proportional to |ω| <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> ) modulation of the frequency of an oscillator. The theory is applied in classifying the types of noise on the signals of frequency standards made available at NBS, Boulder Laboratories, such as: masers (both H and N <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">15</sup> H <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf> ), the cesium beam frequency standard employed as the U. S. Frequency Standard, and rubidium gas cells. "Flicker noise" frequency modulation was not observed on the signals of masers for sampling times ranging from 0.1 second to 4 hours. In a comparison between the NBS hydrogen maser and the NBS III cesium beam, uncorrelated random noise was observed on the frequency fluctuations for sampling times extending to 4 hours; the fractional standard deviations of the frequency fluctuations were as low as 5 parts in 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">14</sup> .

Spectroscopy and Laser ApplicationsAdvanced Frequency and Time StandardsScientific Measurement and Uncertainty EvaluationAllan varianceStandard deviationFrequency standardHydrogen maserMaserNoise (video)FlickerStatisticsFrequency modulationFrequency deviation
Citations
2,628
FWCI
6.42
field-weighted impact
References
14
Percentile
98%
vs. same field & year
Citations per year
Cited by
Characterization of Frequency Stability
IEEE Transactions on Instrumentation and Measurement · 1971 · 790 citations
Analysis and Modeling of Inertial Sensors Using Allan Variance
IEEE Transactions on Instrumentation and Measurement · 2007 · 848 citations
Quantum sensing
Reviews of Modern Physics · 2017 · 3,698 citations
References
An Introduction to Fourier Analysis and Generalized Functions.
American Mathematical Monthly · 1959 · 920 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.