Scinovex
articleTop 1% cited

PET-CT image registration in the chest using free-form deformations

IEEE Transactions on Medical Imaging · 2003 · Vol. 22(1) · pp. 120–128
David MattesDavid R. HaynorHubert VesselleT.K. LewellenWilliam B. Eubank

Abstract

We have implemented and validated an algorithm for three-dimensional positron emission tomography transmission-to-computed tomography registration in the chest, using mutual information as a similarity criterion. Inherent differences in the two imaging protocols produce significant nonrigid motion between the two acquisitions. A rigid body deformation combined with localized cubic B-splines is used to capture this motion. The deformation is defined on a regular grid and is parameterized by potentially several thousand coefficients. Together with a spline-based continuous representation of images and Parzen histogram estimates, our deformation model allows closed-form expressions for the criterion and its gradient. A limited-memory quasi-Newton optimization algorithm is used in a hierarchical multiresolution framework to automatically align the images. To characterize the performance of the method, 27 scans from patients involved in routine lung cancer staging were used in a validation study. The registrations were assessed visually by two expert observers in specific anatomic locations using a split window validation technique. The visually reported errors are in the 0- to 6-mm range and the average computation time is 100 min on a moderate-performance workstation.

Medical Imaging Techniques and ApplicationsMedical Image Segmentation TechniquesMedical Imaging and AnalysisImage registrationComputer visionArtificial intelligenceComputer scienceHistogramFree-form deformationKernel (algebra)Parameterized complexityMutual informationRigid transformation

MeSH terms

AlgorithmsCarcinoma, Non-Small-Cell LungHumansLung NeoplasmsMotionSubtraction TechniqueRadiography, ThoracicThoraxTomography, Emission-ComputedArtifactsRadiopharmaceuticalsFluorodeoxyglucose F18

Funding

  • University of Washington
Citations
874
FWCI
20.37
field-weighted impact
References
40
Percentile
100%
vs. same field & year
Citations per year
Cited by
Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets
IEEE Transactions on Medical Imaging · 2009 · 1,115 citations
elastix: A Toolbox for Intensity-Based Medical Image Registration
IEEE Transactions on Medical Imaging · 2009 · 4,269 citations
References
Alignment by Maximization of Mutual Information
International Journal of Computer Vision · 1997 · 2,580 citations
A survey of image registration techniques
ACM Computing Surveys · 1992 · 4,027 citations
Multimodality image registration by maximization of mutual information
IEEE Transactions on Medical Imaging · 1997 · 4,493 citations
B-spline signal processing. I. Theory
IEEE Transactions on Signal Processing · 1993 · 923 citations
An overlap invariant entropy measure of 3D medical image alignment
Pattern Recognition · 1999 · 2,176 citations
Nonrigid registration using free-form deformations: application to breast MR images
IEEE Transactions on Medical Imaging · 1999 · 5,244 citations
Related articles
Nonrigid registration using free-form deformations: application to breast MR images
IEEE Transactions on Medical Imaging · 1999 · 5,244 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.