Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging

Magnetic Resonance in Medicine · 2005 · Vol. 54(3) · pp. 636–644
Scott B. ReederAngel R. PinedaZhifei WenAnn ShimakawaHuanzhou YuJean H. BrittainGarry E. GoldChristopher BeaulieuNorbert J. Pelc

Abstract

Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2pi/3, with the middle echo centered at pi/2+pik (k=any integer), i.e., (-pi/6+pik, pi/2+pik, 7pi/6+pik). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.

Advanced MRI Techniques and ApplicationsNMR spectroscopy and applicationsAdvanced NMR Techniques and ApplicationsEcho (communications protocol)Noise (video)Spin echoImaging phantomAlgorithmMathematicsPhysicsNuclear magnetic resonanceChemistryComputer science

MeSH terms

Adipose TissueAlgorithmsBody WaterHumansImage EnhancementImage Processing, Computer-AssistedMagnetic Resonance ImagingLeast-Squares AnalysisArtifactsPhantoms, Imaging
Citations
698
FWCI
13.37
field-weighted impact
References
33
Percentile
99%
vs. same field & year
Citations per year
References
Simple proton spectroscopic imaging.
Radiology · 1984 · 2,235 citations
SENSE: Sensitivity encoding for fast MRI
Magnetic Resonance in Medicine · 1999 · 6,058 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging · Scinovex