Scinovex
articleTop 1% cited

A comparison of similarity measures for use in 2-D-3-D medical image registration

IEEE Transactions on Medical Imaging · 1998 · Vol. 17(4) · pp. 586–595

Abstract

A comparison of six similarity measures for use in intensity-based two-dimensional-three-dimensional (2-D-3-D) image registration is presented. The accuracy of the similarity measures are compared to a "gold-standard" registration which has been accurately calculated using fiducial markers. The similarity measures are used to register a computed tomography (CT) scan of a spine phantom to a fluoroscopy image of the phantom. The registration is carried out within a region-of-interest in the fluoroscopy image which is user defined to contain a single vertebra. Many of the problems involved in this type of registration are caused by features which were not modeled by a phantom image alone. More realistic "gold-standard" data sets were simulated using the phantom image with clinical image features overlaid. Results show that the introduction of soft-tissue structures and interventional instruments into the phantom image can have a large effect on the performance of some similarity measures previously applied to 2-D-3-D image registration. Two measures were able to register accurately and robustly even when soft-tissue structures and interventional instruments were present as differences between the images. These measures were pattern intensity and gradient difference. Their registration accuracy, for all the rigid-body parameters except for the source to film translation, was within a root-mean-square (rms) error of 0.54 mm or degrees to the "gold-standard" values. No failures occurred while registering using these measures.

Medical Image Segmentation TechniquesMedical Imaging Techniques and ApplicationsMedical Imaging and AnalysisImaging phantomImage registrationFiducial markerSimilarity (geometry)Artificial intelligenceComputer visionFluoroscopyComputer scienceGold standard (test)Medical imaging

MeSH terms

AlgorithmsFluoroscopyHumansSpineTomography, X-Ray ComputedPhantoms, Imaging
Citations
780
FWCI
15.63
field-weighted impact
References
23
Percentile
99%
vs. same field & year
Citations per year
Cited by
elastix: A Toolbox for Intensity-Based Medical Image Registration
IEEE Transactions on Medical Imaging · 2009 · 4,269 citations
Mutual-information-based registration of medical images: a survey
IEEE Transactions on Medical Imaging · 2003 · 2,874 citations
Medical image registration
Physics in Medicine and Biology · 2001 · 2,073 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

A comparison of similarity measures for use in 2-D-3-D medical image registration · Scinovex