Scinovex
articleTop 1% cited

A Wavelet-Based ECG Delineator: Evaluation on Standard Databases

IEEE Transactions on Biomedical Engineering · 2004 · Vol. 51(4) · pp. 570–581
Juan Pablo Martí­nezRute AlmeidaSalvador Carrión OlmosAna Paula RochaPablo Laguna

Abstract

In this paper, we developed and evaluated a robust single-lead electrocardiogram (ECG) delineation system based on the wavelet transform (WT). In a first step, QRS complexes are detected. Then, each QRS is delineated by detecting and identifying the peaks of the individual waves, as well as the complex onset and end. Finally, the determination of P and T wave peaks, onsets and ends is performed. We evaluated the algorithm on several manually annotated databases, such as MIT-BIH Arrhythmia, QT, European ST-T and CSE databases, developed for validation purposes. The QRS detector obtained a sensitivity of Se = 99.66% and a positive predictivity of P+ = 99.56% over the first lead of the validation databases (more than 980,000 beats), while for the well-known MIT-BIH Arrhythmia Database, Se and P+ over 99.8% were attained. As for the delineation of the ECG waves, the mean and standard deviation of the differences between the automatic and manual annotations were computed. The mean error obtained with the WT approach was found not to exceed one sampling interval, while the standard deviations were around the accepted tolerances between expert physicians, outperforming the results of other well known algorithms, especially in determining the end of T wave.

ECG Monitoring and AnalysisCardiac electrophysiology and arrhythmiasEEG and Brain-Computer InterfacesQRS complexStandard deviationWavelet transformPattern recognition (psychology)Artificial intelligenceWaveletComputer scienceQT intervalElectrocardiographySensitivity (control systems)

MeSH terms

AlgorithmsArrhythmias, CardiacDiagnosis, Computer-AssistedElectrocardiographyHeart RateHumansPattern Recognition, AutomatedPrognosisSensitivity and SpecificitySignal Processing, Computer-AssistedReproducibility of ResultsDatabases, Factual
Citations
1,610
FWCI
17.39
field-weighted impact
References
45
Percentile
99%
vs. same field & year
Citations per year
References
Characterization of signals from multiscale edges
IEEE Transactions on Pattern Analysis and Machine Intelligence · 1992 · 2,534 citations
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
IEEE Transactions on Biomedical Engineering · 1986 · 1,138 citations
A comparison of the noise sensitivity of nine QRS detection algorithms
IEEE Transactions on Biomedical Engineering · 1990 · 1,052 citations
ECG beat detection using filter banks
IEEE Transactions on Biomedical Engineering · 1999 · 734 citations
A Real-Time QRS Detection Algorithm
IEEE Transactions on Biomedical Engineering · 1985 · 7,635 citations
Detection of ECG characteristic points using wavelet transforms
IEEE Transactions on Biomedical Engineering · 1995 · 1,595 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.