Scinovex
article

Coronal alignment after total knee replacement

Journal of Bone and Joint Surgery - British Volume · 1991 · Vol. 73-B(5) · pp. 709–714
R.S. JefferyRichard MorrisR. A. Denham

Abstract

Maquet's line passes from the centre of the femoral head to the centre of the body of the talus. The distance of this line from the centre of the knee on a long-leg radiograph provides the most accurate measure of coronal alignment. Malalignment causes abnormal forces which may lead to loosening after knee replacement. We report a series of 115 Denham knee replacements performed between 1976 and 1981 using the earliest design of components, inserted with intramedullary guide rods. Patients were assessed clinically and long-leg standing radiographs were taken before operation, soon after surgery and up to 12 years later. In two-thirds of the knees (68%) Maquet's line passed through the middle third of the prosthesis on postoperative films and the incidence of subsequent loosening was 3%. When Maquet's line was medial or lateral to this, an error of approximately +/- 3 degrees, the incidence of loosening at a median period of eight years was 24%. This difference is highly significant (p = 0.001). Accurate coronal alignment appears to be an important factor in prevention of loosening. Means of improving the accuracy of alignment and of measuring it on long-leg radiographs are discussed.

Foot and Ankle SurgeryLower Extremity Biomechanics and PathologiesTotal Knee Arthroplasty OutcomesCoronal planeRadiographyIntramedullary rodMedicineProsthesisKnee JointOrthodonticsTotal knee replacementOrthopedic surgerySurgery

MeSH terms

AdultAgedAged, 80 and overFemaleFollow-Up StudiesHumansKnee JointKnee ProsthesisMaleMiddle AgedOrthopedic Fixation DevicesProsthesis DesignProsthesis FailureRadiographyReoperation
Citations
1,087
FWCI
2.05
field-weighted impact
References
0
Percentile
87%
vs. same field & year
Citations per year
Cited by
Clinical profile of patients with osteoarthritis underwent total knee arthroplasty
International Journal of Orthopaedics Sciences · 2020 · 2 citations
Long term outcome analysis of fixed bearing total knee arthroplasty
International Journal of Orthopaedics Sciences · 2018 · 0 citations
Total knee arthroplasty in severe varus osteoarthritis knee: A prospective study
International Journal of Orthopaedics Sciences · 2018 · 0 citations
Alignment in total knee arthroplasty
Journal of Bone and Joint Surgery - British Volume · 2004 · 673 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.