Scinovex
article Open AccessTop 1% cited

Axcaliber: A method for measuring axon diameter distribution from diffusion MRI

Magnetic Resonance in Medicine · 2008 · Vol. 59(6) · pp. 1347–1354
Yaniv AssafTamar Blumenfeld‐KatzirYossi YovelPeter J. Basser

Abstract

The diameter of a myelinated nerve axon is directly proportional to its conduction velocity, so the axon diameter distribution helps determine the channel capacity of nervous transmission along fascicles in the central (CNS) and peripheral nervous systems (PNS). Previously, this histological information could only be obtained using invasive tissue biopsies. Here we propose a new NMR-based approach that employs a model of water diffusion within "restricted" cylindrical axons to estimate their diameter distribution within a nerve bundle. This approach can be combined with MRI to furnish an estimate of the axon diameter distribution within each voxel. This method is validated by comparing the diameter distributions measured using the NMR and histological techniques on sciatic and optic nerve tissue specimens. The axon diameter distribution measured in each voxel of porcine spinal cord using MRI and using histological methods were similar. Applications are expected in longitudinal studies designed to follow nerve growth in normal and abnormal development, as well as in diagnosing disorders and diseases affecting specific populations of axons in the CNS and PNS.

Advanced Neuroimaging Techniques and ApplicationsBone and Joint DiseasesSpinal Dysraphism and MalformationsAxonVoxelSciatic nerveDiffusion MRISpinal cordDistribution (mathematics)Central nervous systemAnatomyPeripheral nervous systemNuclear magnetic resonance

MeSH terms

AnimalsAxonsImage Processing, Computer-AssistedMagnetic Resonance SpectroscopyOptic NerveSciatic NerveSpinal CordStaining and LabelingSwineDiffusion Magnetic Resonance Imaging

Funding

  • Israel Science Foundation
  • Tel Aviv University
  • National Institutes of Health
  • National Institute of Child Health and Human Development
Citations
859
FWCI
21.77
field-weighted impact
References
43
Percentile
100%
vs. same field & year
Citations per year
References
MR diffusion tensor spectroscopy and imaging
Biophysical Journal · 1994 · 6,003 citations
Diffusion tensor MR imaging of the human brain.
Radiology · 1996 · 2,681 citations
In vivo fiber tractography using DT-MRI data
Magnetic Resonance in Medicine · 2000 · 3,045 citations
Toward a quantitative assessment of diffusion anisotropy
Magnetic Resonance in Medicine · 1996 · 2,418 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Axcaliber: A method for measuring axon diameter distribution from diffusion MRI · Scinovex