IEEE Transactions on Medical Imaging · 1998 · Vol. 17(5) · pp. 694–702
J. Michael FitzpatrickJay B. WestCalvin R. Maurer

Abstract

Guidance systems designed for neurosurgery, hip surgery, and spine surgery, and for approaches to other anatomy that is relatively rigid can use rigid-body transformations to accomplish image registration. These systems often rely on point-based registration to determine the transformation, and many such systems use attached fiducial markers to establish accurate fiducial points for the registration, the points being established by some fiducial localization process. Accuracy is important to these systems, as is knowledge of the level of that accuracy. An advantage of marker-based systems, particularly those in which the markers are bone-implanted, is that registration error depends only on the fiducial localization error (FLE) and is thus to a large extent independent of the particular object being registered. Thus, it should be possible to predict the clinical accuracy of marker-based systems on the basis of experimental measurements made with phantoms or previous patients. This paper presents two new expressions for estimating registration accuracy of such systems and points out a danger in using a traditional measure of registration accuracy. The new expressions represent fundamental theoretical results with regard to the relationship between localization error and registration error in rigid-body, point-based registration. Rigid-body, point-based registration is achieved by finding the rigid transformation that minimizes "fiducial registration error" (FRE), which is the root mean square distance between homologous fiducials after registration. Closed form solutions have been known since 1966. The expected value (FRE2) depends on the number N of fiducials and expected squared value of FLE, (FLE-2, but in 1979 it was shown that (FRE2) is approximately independent of the fiducial configuration C. The importance of this surprising result seems not yet to have been appreciated by the registration community: Poor registrations caused by poor fiducial configurations may appear to be good due to a small FRE value. A more critical and direct measure of registration error is the "target registration error" (TRE), which is the distance between homologous points other than the centroids of fiducials. Efforts to characterize its behavior have been made since 1989. Published numerical simulations have shown that (TRE2) is roughly proportional to (FLE2)/N and, unlike (FRE2), does depend in some way on C. Thus, FRE, which is often used as feedback to the surgeon using a point-based guidance system, is in fact an unreliable indicator of registration-accuracy. In this work we derive approximate expressions for (TRE2), and for the expected squared alignment error of an individual fiducial. We validate both approximations through numerical simulations. The former expression can be used to provide reliable feedback to the surgeon during surgery and to guide the placement of markers before surgery, or at least to warn the surgeon of potentially dangerous fiducial placements; the latter expression leads to a surprising conclusion: Expected registration accuracy (TRE) is worst near the fiducials that are most closely aligned! This revelation should be of particular concern to surgeons who may at present be relying on fiducial alignment as an indicator of the accuracy of their point-based guidance systems.

Medical Imaging and AnalysisAdvanced X-ray and CT ImagingMedical Imaging Techniques and ApplicationsFiducial markerImage registrationRigid transformationComputer scienceArtificial intelligenceComputer visionTransformation (genetics)Rigid bodyMean squared errorPoint (geometry)

MeSH terms

HumansImage Processing, Computer-AssistedSurgical Procedures, OperativeTherapy, Computer-AssistedTomography, X-Ray Computed
Citations
1,002
FWCI
15.37
field-weighted impact
References
44
Percentile
100%
vs. same field & year
Citations per year
Cited by
Deformable Medical Image Registration: A Survey
IEEE Transactions on Medical Imaging · 2013 · 1,514 citations
Medical image registration
Physics in Medicine and Biology · 2001 · 2,073 citations
References
Procrustes Methods in the Statistical Analysis of Shape
Journal of the Royal Statistical Society Series B (Statistical Methodology) · 1991 · 2,026 citations
Least-Squares Fitting of Two 3-D Point Sets
IEEE Transactions on Pattern Analysis and Machine Intelligence · 1987 · 3,879 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.