article Open AccessTop 1% cited
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Magnetic Resonance in Medicine · 2013 · Vol. 71(3) · pp. 990–1001
Martin Uecker(University of California, Berkeley)Peng Lai(Applied Sciences Laboratory (United States))Mark Murphy(University of California, Berkeley)Patrick Virtue(University of California, Berkeley)Michael Elad(Technion – Israel Institute of Technology)John M. Pauly(Resonance Research (United States))Shreyas Vasanawala(Stanford University)Michael Lustig✉(University of California, Berkeley)
Abstract
In this article the gap between both approaches is finally bridged. A new autocalibration technique combines the benefits of both.
Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMedical Imaging Techniques and ApplicationsComputer scienceEigenvalues and eigenvectorsPhysics
MeSH terms
AlgorithmsCalibrationImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingSensitivity and SpecificityReproducibility of ResultsInformation Storage and RetrievalInternationality
Funding
- American Heart Association
- GE Healthcare
Citations
1,360
FWCI
28.60
field-weighted impact
References
36
Percentile
100%
vs. same field & year
Citations per year
Cited by
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
IEEE Transactions on Medical Imaging · 2018 · 955 citations
A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction
IEEE Transactions on Medical Imaging · 2017 · 1,336 citations
Learning a variational network for reconstruction of accelerated MRI data
Magnetic Resonance in Medicine · 2017 · 1,659 citations
References
The Retrieval of Harmonics from a Covariance Function
Geophysical Journal International · 1973 · 1,114 citations
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary <i>k</i>‐space
Magnetic Resonance in Medicine · 2010 · 810 citations
Sparse MRI: The application of compressed sensing for rapid MR imaging
Magnetic Resonance in Medicine · 2007 · 6,856 citations
The Design and Implementation of FFTW3
Proceedings of the IEEE · 2005 · 5,062 citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Magnetic Resonance in Medicine · 2002 · 5,259 citations
Multiple emitter location and signal parameter estimation
IEEE Transactions on Antennas and Propagation · 1986 · 14,098 citations
Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
Magnetic Resonance in Medicine · 2007 · 804 citations
Advances in sensitivity encoding with arbitrary <i>k</i>‐space trajectories
Magnetic Resonance in Medicine · 2001 · 1,205 citations
Citation Network
How this paper connects to the literature. Drag to explore, click any node to open that paper.