Scinovex
article

A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array

IEEE Transactions on Biomedical Engineering · 1991 · Vol. 38(8) · pp. 758–768
Penny K. CampbellK.E. JonesRobert J. HuberK.W. HorchRichard A. Normann

Abstract

A method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilitate cortical penetration. Each needle is electrically isolated from the other needles, and is about 0.09 mm thick at its base and 1.5 mm long. The sharpened end of each needle is coated with platinum to facilitate charge transfer into neural tissue. The following manufacturing processes were used to create this array. 1) Thermomigration of 100 aluminum pads through an n-type silicon block. This creates trails of highly conductive p+ silicon isolated from each other by opposing pn junctions. 2) A combination of mechanical and chemical micromachining which creates individual penetrating needles of the p+ silicon trails. 3) Metal deposition to create active electrode areas and electrical contact pads. 4) Array encapsulation with polyimide. The geometrical, mechanical, and electrical properties of these arrays should make them well suited as interfaces to cortical tissue.

Neuroscience and Neural EngineeringEEG and Brain-Computer InterfacesNeural dynamics and brain functionMaterials scienceSiliconElectrodeElectrode arrayElectrical conductorMonocrystalline siliconSubstrate (aquarium)Surface micromachiningOptoelectronicsNanotechnology

MeSH terms

AnimalsBiocompatible MaterialsCatsElectric ConductivityElectric StimulationElectrodes, ImplantedMaterials TestingMicroscopy, Electron, ScanningSiliconSomatosensory CortexReproducibility of Results
Citations
864
FWCI
1.60
field-weighted impact
References
25
Percentile
84%
vs. same field & year
Citations per year
Cited by
Microneedle array for transdermal biological fluid extraction and in situ analysis
Sensors and Actuators A Physical · 2004 · 335 citations
Recent advances in flexible sensors for wearable and implantable devices
Journal of Applied Polymer Science · 2013 · 447 citations
References
The sensations produced by electrical stimulation of the visual cortex
The Journal of Physiology · 1968 · 1,167 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array · Scinovex