Scinovex
article Open AccessTop 1% cited

Regularized, fast, and robust analytical Q‐ball imaging

Magnetic Resonance in Medicine · 2007 · Vol. 58(3) · pp. 497–510
Maxime DescoteauxElaine AngelinoShaun FitzgibbonsRachid Deriche

Abstract

We propose a regularized, fast, and robust analytical solution for the Q-ball imaging (QBI) reconstruction of the orientation distribution function (ODF) together with its detailed validation and a discussion on its benefits over the state-of-the-art. Our analytical solution is achieved by modeling the raw high angular resolution diffusion imaging signal with a spherical harmonic basis that incorporates a regularization term based on the Laplace-Beltrami operator defined on the unit sphere. This leads to an elegant mathematical simplification of the Funk-Radon transform which approximates the ODF. We prove a new corollary of the Funk-Hecke theorem to obtain this simplification. Then, we show that the Laplace-Beltrami regularization is theoretically and practically better than Tikhonov regularization. At the cost of slightly reducing angular resolution, the Laplace-Beltrami regularization reduces ODF estimation errors and improves fiber detection while reducing angular error in the ODF maxima detected. Finally, a careful quantitative validation is performed against ground truth from synthetic data and against real data from a biological phantom and a human brain dataset. We show that our technique is also able to recover known fiber crossings in the human brain and provides the practical advantage of being up to 15 times faster than original numerical QBI method.

Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsMRI in cancer diagnosisUnit sphereRegularization (linguistics)Spherical harmonicsImaging phantomTikhonov regularizationMathematicsLaplace transformMathematical analysisAlgorithmComputer science

MeSH terms

AlgorithmsAnimalsBrainFourier AnalysisHumansImage EnhancementImage Processing, Computer-AssistedModels, TheoreticalNerve FibersSpinal CordTime FactorsArtifactsRats, Sprague-DawleyEcho-Planar ImagingPhantoms, Imaging

Funding

  • McGill University
  • Max-Planck-Institut für Kognitions- und Neurowissenschaften
Citations
841
FWCI
39.28
field-weighted impact
References
39
Percentile
100%
vs. same field & year
Citations per year
Cited by
Free water elimination and mapping from diffusion MRI
Magnetic Resonance in Medicine · 2009 · 1,080 citations
Generalized ${ q}$-Sampling Imaging
IEEE Transactions on Medical Imaging · 2010 · 1,044 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.