Scinovex
article Open AccessTop 1% cited

Additively Manufactured Open-Cell Porous Biomaterials Made from Six Different Space-Filling Unit Cells: The Mechanical and Morphological Properties

Materials · 2015 · Vol. 8(4) · pp. 1871–1896
S.M. AhmadiSaber Amin YavariR. WauthleBehdad PouranJan SchrootenHarrie WeinansAmir A. Zadpoor

Abstract

It is known that the mechanical properties of bone-mimicking porous biomaterials are a function of the morphological properties of the porous structure, including the configuration and size of the repeating unit cell from which they are made. However, the literature on this topic is limited, primarily because of the challenge in fabricating porous biomaterials with arbitrarily complex morphological designs. In the present work, we studied the relationship between relative density (RD) of porous Ti6Al4V EFI alloy and five compressive properties of the material, namely elastic gradient or modulus (E<sub>s20</sub><sub>-70</sub>), first maximum stress, plateau stress, yield stress, and energy absorption. Porous structures with different RD and six different unit cell configurations (cubic (C), diamond (D), truncated cube (TC), truncated cuboctahedron (TCO), rhombic dodecahedron (RD), and rhombicuboctahedron (RCO)) were fabricated using selective laser melting. Each of the compressive properties increased with increase in RD, the relationship being of a power law type. Clear trends were seen in the influence of unit cell configuration and porosity on each of the compressive properties. For example, in terms of E<sub>s20</sub><sub>-70</sub>, the structures may be divided into two groups: those that are stiff (comprising those made using C, TC, TCO, and RCO unit cell) and those that are compliant (comprising those made using D and RD unit cell).

Bone Tissue Engineering MaterialsAdditive Manufacturing Materials and ProcessesAdditive Manufacturing and 3D Printing TechnologiesMaterials sciencePorositySelective laser meltingComposite materialCompressive strengthElastic modulusMicrostructure
Citations
388
FWCI
15.24
field-weighted impact
References
81
Percentile
99%
vs. same field & year
Citations per year
References
Selective laser melting of aluminium components
Journal of Materials Processing Technology · 2010 · 890 citations
Mechanical properties of biomedical titanium alloys
Materials Science and Engineering A · 1998 · 2,096 citations
Mechanobiology of Skeletal Regeneration
Clinical Orthopaedics and Related Research · 1998 · 748 citations
Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results
Journal of Bone and Joint Surgery - British Volume · 1987 · 1,760 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Additively Manufactured Open-Cell Porous Biomaterials Made from Six Different Space-Filling Unit Cells: The Mechanical and Morphological Properties · Scinovex