Scinovex
articleTop 10% cited

A CRITICAL EVALUATION OF SONAR “CROWN‐RUMP LENGTH” MEASUREMENTS

BJOG An International Journal of Obstetrics & Gynaecology · 1975 · Vol. 82(9) · pp. 702–710
Hugh P. RobinsonJ. E. E. Fleming

Abstract

In a study to evaluate the reproducibility and accuracy of the sonar technique of measurement of the in vivo fetal crown-rump length (Robinson, 1973), a series of in vivo and in vitro experiments was performed in which the random and systematic errors inherent in the technique were assessed. The potential sources of random error were those of operator judgement, movement of the fetus and mother, machine sensitivity settings and measurement from the photograph; while the sources of systematic error were those of oscilloscope scale factor, and velocity calibration inaccuracies, and the effect of beam width. The overall effect of the random errors, that is, the reproducibility of the technique, was assessed in an in vivo blind trial in which three independent measurements were made of the fetus. In a series of 30 experiments the average standard deviation of the three readings was found to be 1.2 mm. Evaluation of the systematic errors by in vivo experimentation, on the other hand, showed that the basic sonar measurements were in error by an overestimate of 1 mm for the beam width effect and 3.7 per cent for the scale factor and velocity calibration errors. A weighted non-linear regression analysis of 334 measurements was performed in order to obtain a "curve of best fit" for the period covering 6 to 14 weeks of menstrual age. The values obtained were corrected for the systematic errors and compared with widely quoted anatomical figures. In the second part of this investigation the original data was further analyzed to determine on a statistical basis the accuracy of the technique as a method of estimating maturity. It was shown that such an estimate could be made to within 4.7 days with a 95 per cent probability on the basic of a single measurement, and to within 2.7 days if three independent measurements were made.

Pregnancy and preeclampsia studiesAssisted Reproductive Technology and Twin PregnancyPrenatal Screening and DiagnosticsStandard deviationCalibrationReproducibilityCrown-rump lengthMathematicsStatisticsFirst trimester

MeSH terms

AnthropometryFemaleFetusGestational AgeGrowthHumansPregnancyPregnancy Trimester, FirstTime FactorsUltrasonography
Citations
1,402
FWCI
9.41
field-weighted impact
References
5
Percentile
99%
vs. same field & year
Citations per year
Cited by
Estimation of gestational age in third trimester using mean fetal kidney length in comparison with fetal biometry
International Journal of Clinical Obstetrics and Gynaecology · 2023 · 0 citations
Uterine artery Doppler at 30 – 33 weeks of gestation and pregnancy outcome
International Journal of Clinical Obstetrics and Gynaecology · 2018 · 0 citations
Role of routine ultrasound in first trimester of pregnancy
International Journal of Clinical Obstetrics and Gynaecology · 2023 · 0 citations
Committee Opinion No 700: Methods for Estimating the Due Date
Obstetrics and Gynecology · 2017 · 631 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

A CRITICAL EVALUATION OF SONAR “CROWN‐RUMP LENGTH” MEASUREMENTS · Scinovex