Abstract

A model based upon steady-state diffusion theory which describes the radial dependence of diffuse reflectance of light from tissues is developed. This model incorporates a photon dipole source in order to satisfy the tissue boundary conditions and is suitable for either refractive index matched or mismatched surfaces. The predictions of the model were compared with Monte Carlo simulations as well as experimental measurements made with tissue simulating phantoms. The model describes the reflectance data accurately to radial distances as small as 0.5 mm when compared to Monte Carlo simulations and agrees with experimental measurements to distances as small as 1 mm. A nonlinear least-squares fitting procedure has been used to determine the tissue optical properties from the radial reflectance data in both phantoms and tissues in vivo. The optical properties derived for the phantoms are within 5%-10% of those determined by other established techniques. The in vivo values are also consistent with those reported by other investigators.

Optical Imaging and Spectroscopy TechniquesClimate Change and Health ImpactsSpaceflight effects on biologyMonte Carlo methodDiffuse reflectance infrared fourier transformDiffuse reflectionDiffusionOpticsPhoton transport in biological tissuePhoton diffusionPhotonMaterials scienceRefractive index

MeSH terms

DiffusionHumansLightMathematicsModels, StructuralModels, TheoreticalMonte Carlo MethodScattering, RadiationSkin
Citations
1,370
FWCI
7.97
field-weighted impact
References
0
Percentile
98%
vs. same field & year
Citations per year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.