Scinovex
articleTop 1% cited

Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments

Magnetic Resonance in Medicine · 2009 · Vol. 61(6) · pp. 1441–1450
Mina KimJoseph GillenBennett A. LandmanJinyuan ZhouPeter C.M. van Zijl

Abstract

Chemical exchange saturation transfer (CEST) is a contrast mechanism that exploits exchange-based magnetization transfer (MT) between solute and water protons. CEST effects compete with direct water saturation and conventional MT processes, and generally can only be quantified through an asymmetry analysis of the water saturation spectrum (Z-spectrum) with respect to the water frequency, a process that is exquisitely sensitive to magnetic field inhomogeneities. Here it is shown that direct water saturation imaging allows measurement of the absolute water frequency in each voxel, allowing proper centering of Z-spectra on a voxel-by-voxel basis independently of spatial B(0) field variations. Optimal acquisition parameters for this "water saturation shift referencing" (WASSR) approach were estimated using Monte Carlo simulations and later confirmed experimentally. The optimal ratio of the WASSR sweep width to the linewidth of the direct saturation curve was found to be 3.3-4.0, requiring a sampling of 16-32 points. The frequency error was smaller than 1 Hz at signal-to-noise ratios of 40 or higher. The WASSR method was applied to study glycogen, where the chemical shift difference between the hydroxyl (OH) protons and bulk water protons at 3T is so small (0.75-1.25 ppm) that the CEST spectrum is inconclusive without proper referencing.

Advanced MRI Techniques and ApplicationsLanthanide and Transition Metal ComplexesMRI in cancer diagnosisSaturation (graph theory)ChemistryNuclear magnetic resonanceVoxelLaser linewidthMonte Carlo methodAnalytical Chemistry (journal)Magnetization transferAsymmetryComputational physics

MeSH terms

AdultAlgorithmsBody WaterFemaleHumansImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingMaleSensitivity and SpecificityWaterReproducibility of ResultsMuscle, Skeletal

Funding

  • National Institutes of Health
Citations
677
FWCI
15.17
field-weighted impact
References
39
Percentile
99%
vs. same field & year
Citations per year
Cited by
Chemical exchange saturation transfer (CEST): What is in a name and what isn't?
Magnetic Resonance in Medicine · 2011 · 1,106 citations
References
SENSE: Sensitivity encoding for fast MRI
Magnetic Resonance in Medicine · 1999 · 6,058 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments · Scinovex