A method for measuring the presampled MTF of digital radiographic systems using an edge test device

Medical Physics · 1998 · Vol. 25(1) · pp. 102–113
Ehsan SameiMichael FlynnDavid A. Reimann

Abstract

The modulation transfer function (MTF) of radiographic systems is frequently evaluated by measuring the system's line spread function (LSF) using narrow slits. The slit method requires precise fabrication and alignment of a slit and high radiation exposure. An alternative method for determining the MTF uses a sharp, attenuating edge device. We have constructed an edge device from a 250-microm-thick lead foil laminated between two thin slabs of acrylic. The device is placed near the detector and aligned with the aid of a laser beam and a holder such that a polished edge is parallel to the x-ray beam. A digital image of the edge is processed to obtain the presampled MTF. The image processing includes automated determination of the edge angle, reprojection, sub-binning, smoothing of the edge spread function (ESF), and spectral estimation. This edge method has been compared to the slit method using measurements on standard and high-resolution imaging plates of a digital storage phosphor (DSP) radiography system. The experimental results for both methods agree with a mean MTF difference of 0.008. The edge method provides a convenient measurement of the presampled MTF for digital radiographic systems with good response at low frequencies.

Digital Radiography and Breast ImagingAdvanced X-ray and CT ImagingOptical Systems and Laser TechnologyOptical transfer functionOpticsDigital radiographyComputed radiographyEdge enhancementDetectorEnhanced Data Rates for GSM EvolutionFlat panel detectorMaterials scienceRadiography

MeSH terms

Computer SimulationImage Processing, Computer-AssistedLasersRadiographic Image EnhancementX-Ray Intensifying ScreensReproducibility of Results

Funding

  • University of Michigan
  • Henry Ford Health System
  • American Association of Physicists in Medicine
Citations
739
FWCI
4.98
field-weighted impact
References
45
Percentile
95%
vs. same field & year
Citations per year
References
Use of the Hough transformation to detect lines and curves in pictures
Communications of the ACM · 1972 · 6,470 citations
The Fourier Transform and Its Applications
American Journal of Physics · 1966 · 5,454 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

A method for measuring the presampled MTF of digital radiographic systems using an edge test device · Scinovex