articleTop 1% cited
First performance evaluation of a dual-source CT (DSCT) system
European Radiology · 2005 · Vol. 16(2) · pp. 256–268
Thomas Flohr✉(Siemens (Germany))Cynthia H. McCollough(Mayo Clinic)Herbert Bruder(Siemens (Germany))Martin Petersilka(Siemens (Germany))Klaus Gruber(Siemens (Germany))Christoph Süβ(Siemens (Germany))Michael Grasruck(Siemens (Germany))Karl Stierstorfer(Siemens (Germany))Bernhard Krauß(Siemens (Germany))Rainer Raupach(Siemens (Germany))Andrew N. Primak(Mayo Clinic)Axel Küttner(Friedrich-Alexander-Universität Erlangen-Nürnberg)Stefan Achenbach(Friedrich-Alexander-Universität Erlangen-Nürnberg)Christoph R. Becker(Ludwig-Maximilians-Universität München)Andreas F. Kopp(University of Tübingen)Bernd Ohnesorge(Siemens (Germany))
Cardiac Imaging and DiagnosticsAdvanced X-ray and CT ImagingRadiation Dose and ImagingNeuroradiologyMedicineImaging phantomTemporal resolutionCardiac imagingImage resolutionOffset (computer science)Interventional radiologyUltrasoundAngiography
MeSH terms
DiastoleElectrocardiographyEquipment DesignHeart RateHumansImage EnhancementImage Processing, Computer-AssistedMaleMiddle AgedSensitivity and SpecificitySystoleTechnology Assessment, BiomedicalCoronary AngiographyPhantoms, ImagingEchocardiography, Four-Dimensional
Citations
1,402
FWCI
73.16
field-weighted impact
References
43
Percentile
100%
vs. same field & year
Citations per year
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
Radiology · 2015 · 1,501 citations
High-resolution X-ray computed tomography in geosciences: A review of the current technology and applications
Earth-Science Reviews · 2013 · 1,501 citations
Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose
European Radiology · 2008 · 292 citations
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
European Radiology · 2008 · 478 citations
Dual-source CT cardiac imaging: initial experience
European Radiology · 2006 · 343 citations
Flat-detector computed tomography (FD-CT)
European Radiology · 2007 · 301 citations
X-ray computed tomography
Physics in Medicine and Biology · 2006 · 664 citations
Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
European Radiology · 2006 · 420 citations
References
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Medical Physics · 1986 · 439 citations
Optimal short scan convolution reconstruction for fan beam CT
Medical Physics · 1982 · 514 citations
Citation Network