Scinovex
article Open AccessTop 10% cited

Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke Model

Journal of Cerebral Blood Flow & Metabolism · 1989 · Vol. 9(5) · pp. 589–596
Ulrich DirnaglBruce KaplanMichael JacewiczWilliam A. Pulsinelli

Abstract

Laser-Doppler flowmetry (LDF), a new method allowing instantaneous, continuous, and noninvasive measurements of microcirculatory blood flow in a small tissue sample, was evaluated for its accuracy in monitoring regional cerebral blood flow (rCBF) in the cortical microcirculation after focal cerebral ischemia. Wistar and spontaneously hypertensive rats (SHR, n = 19) were subjected to permanent occlusion of the middle cerebral and common carotid arteries. Absolute rCBF in a tissue sample of the ischemic hemisphere was measured autoradiographically with [14C]iodoantipyrine as a tracer and compared to rCBF measured by LDF. Additionally, the percent change in rCBF between baseline and ischemic values was compared for both methods. Absolute rCBF values recorded with LDF correlated poorly (r = 0.54) with [14C]iodoantipyrine measurements. In contrast LDF readings expressed as a percentage of ischemic vs. preocclusion readings (relative LDF readings) correlated very well (r = 0.91) with the percent change in [14C]iodoantipyrine measurements. We conclude that LDF does not provide accurate measurements of absolute rCBF values but this method allows accurate measurements of changes in rCBF due to induction of focal cerebral ischemia.

Optical Imaging and Spectroscopy TechniquesThermoregulation and physiological responsesCardiovascular Health and Disease PreventionLaser Doppler velocimetryCerebral blood flowMicrocirculationIschemiaMedicineBlood flowOcclusionHemodynamicsCardiologyInternal medicine

MeSH terms

AnimalsAntipyrineAutoradiographyCarbon RadioisotopesCerebral CortexBrain IschemiaCerebrovascular CirculationCerebrovascular DisordersLasersMaleRats, Inbred SHRReference ValuesRats

Funding

  • Deutscher Akademischer Austauschdienst
Citations
477
FWCI
7.79
field-weighted impact
References
39
Percentile
98%
vs. same field & year
Citations per year
Cited by
Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Journal of Cerebral Blood Flow & Metabolism · 2001 · 817 citations
Non-invasive optical spectroscopy and imaging of human brain function
Trends in Neurosciences · 1997 · 1,604 citations
References
Continuous measurement of tissue blood flow by laser-Doppler spectroscopy
American Journal of Physiology-Heart and Circulatory Physiology · 1977 · 444 citations
Insulin effects on monovalent cation transport and Na-K-ATPase activity
American Journal of Physiology-Cell Physiology · 1978 · 705 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke Model · Scinovex