Atlantoaxial Fixation Using Plate and Screw Method: A Report of 160 Treated Patients

Neurosurgery · 2002 · Vol. 51(6) · pp. 1351–1357
Atul GoelKetan DesaiDattatraya P. Muzumdar

Abstract

The plate and screw method of fixation with the use of intra-articular bone grafts in patients with atlantoaxial instability yielded a 100% fusion rate with a low incidence of complications.

Spinal Fractures and Fixation TechniquesTraumatic Brain Injury and Neurovascular DisturbancesSpine and Intervertebral Disc PathologyMedicineAtlantoaxial instabilitySurgeryFixation (population genetics)NeurosurgeryRadiographyCervical spinePopulation

MeSH terms

AdolescentAdultAgedAtlanto-Axial JointBone PlatesBone ScrewsChildChild, PreschoolJoint DislocationsEquipment FailureFemaleHumansInfantJoint InstabilityMale