Influence of implant length and diameter on stress distribution: A finite element analysis

Journal of Prosthetic Dentistry · 2004 · Vol. 91(1) · pp. 20–25
Lucie HimmlováTaťjana DostálováAlois KácovskýS. Konvičková
Mineral Processing and GrindingRock Mechanics and ModelingConcrete and Cement Materials Researchvon Mises yield criterionMaterials scienceImplantFinite element methodStress (linguistics)Masticatory forceOrthodonticsBiomedical engineeringStructural engineeringSurgery

MeSH terms

Alveolar ProcessBite ForceComputer SimulationHumansMandibleModels, BiologicalMolarRegression AnalysisStress, MechanicalSurface PropertiesDental ImplantsDental Prosthesis DesignDental Restoration FailureFinite Element AnalysisTooth Socket