Scinovex
article Open AccessTop 1% cited

Simple Telemedicine for Developing Regions: Camera Phones and Paper-Based Microfluidic Devices for Real-Time, Off-Site Diagnosis

Analytical Chemistry · 2008 · Vol. 80(10) · pp. 3699–3707
Andres W. MartinezScott T. PhillipsEmanuel CarrilhoSamuel W. ThomasHayat SindiGeorge M. Whitesides

Abstract

This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.

Biosensors and Analytical DetectionSARS-CoV-2 detection and testingAdvanced biosensing and bioanalysis techniquesMicrofluidicsDigital cameraComputer scienceTelemedicineCalibrationReal-time computingArtificial intelligenceComputer hardwareChemistryNanotechnology

MeSH terms

ColorimetryDiagnosisHumansPaperTelephoneTelemedicineMicrofluidics
Citations
1,428
FWCI
43.00
field-weighted impact
References
48
Percentile
100%
vs. same field & year
Citations per year
References
Rapid Diagnostic Tests for Malaria Parasites
Clinical Microbiology Reviews · 2002 · 1,407 citations
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Angewandte Chemie International Edition · 2007 · 2,814 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.