Abstract

Interfacial tension measurements are reported for the (H2O + CO2) system at pressures of (1 to 60) MPa and temperatures of (298 to 374) K. The pendant drop method was implemented using a high-pressure apparatus consisting of a view cell, fitted with a high-pressure capillary tube for creating pendant H2O drops in the CO2 bulk phase. The reported results have a relative standard deviation in most cases of less than 1.0 % and are in good agreement with literature values at low pressures. However, at higher pressures (up to 45 MPa), there is a significant scatter in the published data; the reasons for this are discussed. Measurements in the present work extend the pressure range of available data up to pressures of 60 MPa.

Phase Equilibria and ThermodynamicsCarbon Dioxide Capture TechnologiesAtmospheric and Environmental Gas DynamicsChemistrySurface tensionCapillary actionThermodynamicsRelative standard deviationAnalytical Chemistry (journal)Pressure measurementDrop (telecommunication)Tension (geology)Absolute deviation