Corrosion characterization of titanium alloys by electrochemical techniques
Electrochimica Acta · 2005 · Vol. 51(8-9) · pp. 1815–1819
Sérgio Luiz de Assis✉(National Nuclear Energy Commission)Stephan Wolynec(Universidade de São Paulo)Isolda Costa(National Nuclear Energy Commission)
Titanium Alloys Microstructure and PropertiesHydrogen embrittlement and corrosion behaviors in metalsOrthopaedic implants and arthroplastyDielectric spectroscopyCorrosionMaterials sciencePolarization (electrochemistry)TitaniumTitanium alloyConstant phase elementEquivalent circuitOxideAlloy
Citations
785
FWCI
8.84
field-weighted impact
References
22
Percentile
99%
vs. same field & year
Citations per year
Cited by
Effects of scan rate on the potentiodynamic polarization curve obtained to determine the Tafel slopes and corrosion current density
Corrosion Science · 2008 · 494 citations
Antibacterial activity and increased bone marrow stem cell functions of Zn-incorporated TiO2 coatings on titanium
Acta Biomaterialia · 2011 · 483 citations
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Materials Science and Engineering C · 2019 · 1,389 citations
Corrosion behavior of selective laser melted Ti-6Al-4 V alloy in NaCl solution
Corrosion Science · 2015 · 542 citations
References
Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application
Electrochimica Acta · 1996 · 660 citations
Design and mechanical properties of new β type titanium alloys for implant materials
Materials Science and Engineering A · 1998 · 1,254 citations
The use of titanium for medical applications in the USA
Materials Science and Engineering A · 1996 · 834 citations
Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications
Journal of Electroanalytical Chemistry · 1999 · 536 citations