Scinovex
article Open Access

Density Fluctuation Measurements Using a Frequency Hopping Reflectometer in JT-60U

Plasma and Fusion Research · 2011 · Vol. 6 · pp. 1402014–1402014
N. OyamaH. TakenagaT. SuzukiY. SakamotoA. Isayamathe JT- Team

Abstract

In JT-60U, a frequency hopping reflectometer has been developed to evaluate the poloidal rotation velocity as a Doppler reflectometer and the radial correlation of density fluctuations in plasmas. The system can measure the radial profile of density fluctuations or the radial correlation profile at two spatial points within 250 ms by combining with the other fixed frequency reflectometer. The radial profiles of the poloidal rotation velocity evaluated from the Doppler-shifted frequency spectrum of density fluctuations show a positive radial electric field in co-rotating plasmas and a negative radial electric field in counter-rotating plasmas. Density fluctuation measurement at the internal transport barrier (ITB) using a correlation reflectometer revealed that long-range correlation increased when ITB was degraded owing to the central heating by electron cyclotron waves.

Magnetic confinement fusion researchIonosphere and magnetosphere dynamicsSuperconducting Materials and ApplicationsDoppler effectPhysicsPlasmaElectric fieldRotation (mathematics)Radial velocityElectron densityCyclotronPlasma diagnosticsElectron temperature

Funding

  • Japan Society for the Promotion of Science
  • Japan Atomic Energy Agency
Citations
19
FWCI
0.51
field-weighted impact
References
16
Percentile
84%
vs. same field & year
Citations per year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.