Scinovex
article Open AccessTop 1% cited

Loop-Mediated Isothermal Amplification for Direct Detection of <i>Mycobacterium tuberculosis</i> Complex, <i>M. avium</i> , and <i>M. intracellulare</i> in Sputum Samples

Journal of Clinical Microbiology · 2003 · Vol. 41(6) · pp. 2616–2622

Abstract

Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method in which reagents react under isothermal conditions with high specificity, efficiency, and rapidity. We used LAMP for detection of Mycobacterium tuberculosis complex, Mycobacterium avium, and Mycobacterium intracellulare directly from sputum specimens as well as for detection of culture isolates grown in a liquid medium (MGIT; Nippon Becton Dickinson Co., Ltd., Tokyo, Japan) or on a solid medium (Ogawa's medium). Species-specific primers were designed by targeting the gyrB gene, and their specificities were validated on 24 mycobacterial species and 7 nonmycobacterial species. The whole procedure is quite simple, starting with the mixing of all reagents in a single tube, followed by an isothermal reaction during which the reaction mixture is held at 63 degrees C. The resulting amplicons are visualized by adding SYBR Green I to the reaction tube. The only equipment needed for the amplification reaction is a regular laboratory water bath or heat block that furnishes a constant temperature of 63 degrees C. The assay had a detection limit of 5 to 50 copies of purified DNA with a 60-min incubation time. The reaction time could be shortened to 35 min for the species identification of M. tuberculosis complex, M. avium, and M. intracellulare from a solid-medium culture. Residual DNA lysates prepared for the Amplicor assay (Roche Diagnostics GmbH) from 66 sputum specimens were tested in the LAMP assay. Although the sample size used for the latter assay was small, 2.75 micro l of the DNA lysates, it showed a performance comparable with that of the Amplicor assay, which required 50 micro l of the lysates. This LAMP-based assay is simple, rapid, and sensitive; a result is available in 35 min for a solid-medium culture and in 60 min for a liquid-medium culture or for a sputum specimen that contains a corresponding amount of DNA available for testing.

Biosensors and Analytical DetectionMycobacterium research and diagnosisInnovative Microfluidic and Catalytic Techniques InnovationLoop-mediated isothermal amplificationSputumMycobacterium tuberculosisAmpliconMycobacteriumMolecular biologyMicrobiologyDetection limitMycobacterium tuberculosis complexBiology

MeSH terms

AnimalsBase SequenceCulture MediaDNA, BacterialHot TemperatureHumansMolecular Sequence DataMycobacterium InfectionsMycobacterium tuberculosisSensitivity and SpecificitySputumTuberculosis, PulmonaryMycobacterium avium ComplexDNA PrimersNucleic Acid Amplification Techniques
Citations
613
FWCI
13.29
field-weighted impact
References
25
Percentile
99%
vs. same field & year
Citations per year
References
Loop-mediated isothermal amplification of DNA
Nucleic Acids Research · 2000 · 8,626 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Loop-Mediated Isothermal Amplification for Direct Detection of <i>Mycobacterium tuberculosis</i> Complex, <i>M. avium</i> , and <i>M. intracellulare</i> in Sputum Samples · Scinovex