Scinovex
articleTop 10% cited

How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging

NeuroImage · 2003 · Vol. 20(2) · pp. 870–888
Jesper AnderssonStefan SkareJohn Ashburner
Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsMRI in cancer diagnosisDiffusion MRISpin echoEcho (communications protocol)DiffusionEcho-planar imagingPlanarTensor (intrinsic definition)Nuclear magnetic resonanceTree traversalPhysics

MeSH terms

AlgorithmsBrainBrain MappingHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingModels, StatisticalEcho-Planar Imaging

Funding

  • Vetenskapsrådet
Citations
3,661
FWCI
4.56
field-weighted impact
References
46
Percentile
94%
vs. same field & year
Citations per year
References
Fast, automated, <i>N</i>‐dimensional phase‐unwrapping algorithm
Magnetic Resonance in Medicine · 2002 · 711 citations
Nonlinear spatial normalization using basis functions
Human Brain Mapping · 1999 · 1,880 citations
Multimodality image registration by maximization of mutual information
IEEE Transactions on Medical Imaging · 1997 · 4,493 citations
Deformable templates using large deformation kinematics
IEEE Transactions on Image Processing · 1996 · 1,130 citations
Diffusion tensor MR imaging of the human brain.
Radiology · 1996 · 2,681 citations
Voxel-Based Morphometry—The Methods
NeuroImage · 2000 · 8,608 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging · Scinovex