Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter

IEEE Transactions on Power Electronics · 2013 · Vol. 29(7) · pp. 3414–3427
Donghua PanXinbo RuanChenlei BaoWeiwei LiXuehua Wang

Abstract

This paper investigates the capacitor-current-feedback active damping for the digitally controlled LCL-type grid-connected inverter. It turns out that proportional feedback of the capacitor current is equivalent to virtual impedance connected in parallel with the filter capacitor due to the computation and pulse width modulation (PWM) delays. The LCL-filter resonance frequency is changed by this virtual impedance. If the actual resonance frequency is higher than one-sixth of the sampling frequency (f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">s</sub> /6), where the virtual impedance contains a negative resistor component, a pair of open-loop unstable poles will be generated. As a result, the LCL-type grid-connected inverter becomes much easier to be unstable if the resonance frequency is moved closer to f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">s</sub> /6 due to the variation of grid impedance. To address this issue, this paper proposes a capacitor-current-feedback active damping with reduced computation delay, which is achieved by shifting the capacitor current sampling instant towards the PWM reference update instant. With this method, the virtual impedance exhibits more like a resistor in a wider frequency range, and the open-loop unstable poles are removed; thus, high robustness against the grid-impedance variation is acquired. Experimental results from a 6-kW prototype confirm the theoretical expectations.

Microgrid Control and OptimizationAdvanced DC-DC ConvertersIslanding Detection in Power SystemsCapacitorResistorElectrical impedanceInverterPulse-width modulationControl theory (sociology)Robustness (evolution)Damping factorEquivalent impedance transformsComputer science
Citations
756
FWCI
72.82
field-weighted impact
References
30
Percentile
100%
vs. same field & year
Citations per year
References
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
IEEE Transactions on Industry Applications · 2005 · 2,355 citations
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
IEEE Transactions on Industrial Electronics · 2006 · 5,104 citations
Optimized Design of Stationary Frame Three Phase AC Current Regulators
IEEE Transactions on Power Electronics · 2009 · 773 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter · Scinovex