Scinovex
articleTop 10% cited

Precision Measurement of Half-Lives and Specific Activities of<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mmultiscripts><mml:mrow><mml:mi mathvariant="normal">U</mml:mi></mml:mrow><mml:mprescripts/><mml:mrow/><mml:mrow><mml:mn>235</mml:mn></mml:mrow><mml:mrow/><mml:mrow/></mml:mmultiscripts></mml:mrow></mml:math>and<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mmultiscripts><mml:mrow><mml:mi mathvariant="normal">U</mml:mi></mml:mrow><mml:mprescripts/><mml:mrow/><mml:mrow><mml:mn>238</mml:mn></mml:mrow><mml:mrow/><mml:mrow/></mml:mmultiscripts></mml:mrow></mml:math>

Physical Review C · 1971 · Vol. 4(5) · pp. 1889–1906
A.H. JaffeyKian FlynnL.E. GlendeninW. C. BentleyA.M. Essling

Abstract

New determinations of the half-lives of $^{235}\mathrm{U}$ and $^{238}\mathrm{U}$ have been made. Improved techniques have allowed the half-life values to be measured with greater accuracy than has been heretofore achieved. Samples were prepared by molecular plating and counted in a intermediate-geometry $\ensuremath{\alpha}$-proportional counter with an extremely flat pulse-height plateau. The small amount of residual nonplated uranium was counted in a $2\ensuremath{\pi}$ counter. Energy analysis with a silicon-junction detector was used to measure the presence of "foreign" activities. For $^{235}\mathrm{U}$, the measured specific activity was (4798.1\ifmmode\pm\else\textpm\fi{}3.3) (dis/min)/(mg $^{235}\mathrm{U}$), corresponding to a half-life of (7.0381\ifmmode\pm\else\textpm\fi{}0.0048) \ifmmode\times\else\texttimes\fi{} ${10}^{8}$ yr. For $^{238}\mathrm{U}$, the specific activity was measured as (746.19\ifmmode\pm\else\textpm\fi{}0.41) (dis/min)/(mg $^{238}\mathrm{U}$), corresponding to a half-life of (4.4683\ifmmode\pm\else\textpm\fi{}0.0024) \ifmmode\times\else\texttimes\fi{} ${10}^{9}$ yr. Errors quoted are statistical (standard error of the mean), based upon the observed scatter of the data. This scatter exceeds that expected from counting statistics alone. We believe that systematic errors, if present, will no more than double the quoted errors.

Funding

  • National Institute of Environmental Research
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Precision Measurement of Half-Lives and Specific Activities of<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mmultiscripts><mml:mrow><mml:mi mathvariant="normal">U</mml:mi></mml:mrow><mml:mprescripts/><mml:mrow/><mml:mrow><mml:mn>235</mml:mn></mml:mrow><mml:mrow/><mml:mrow/></mml:mmultiscripts></mml:mrow></mml:math>and<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mmultiscripts><mml:mrow><mml:mi mathvariant="normal">U</mml:mi></mml:mrow><mml:mprescripts/><mml:mrow/><mml:mrow><mml:mn>238</mml:mn></mml:mrow><mml:mrow/><mml:mrow/></mml:mmultiscripts></mml:mrow></mml:math> · Scinovex